Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

STAAD.Pro

Showing 441

Staad Pro does not include Seismic load NBCC 2015

Dear All, I highly recommend to include calculation of seismic load using NBCC 2015. I see it as a big gap in Staad Pro not to include Seismic loading using NBCC 2015 Thanks a lot
over 4 years ago in STAAD.Pro 1 Future consideration

Canadian Seismic Load per 2015 NBC code parameters

Would like to get implemented NBC 2015 Code parameter.
over 1 year ago in STAAD.Pro 0 Future consideration

WIND CORNER PRESSURE AND ROOF IN WIND LOAD GENERATOR

Hello i would like to drop my suggestion for consideration, as we know up to now Wind Load generator, can only generate wind on panels. But during design we may have to apply corner wind pressure especially in connection design and also to apply w...
over 2 years ago in STAAD.Pro 2 Needs review

Add the ability to add wind loads to plate elements

It would be nice to be able to apply wind loads on plate elements. Especially given that there is a wind load definition specifically for tanks, but no way to model that tank other than plate elements. The alternatives are a cumbersome to implemen...
over 3 years ago in STAAD.Pro 2 Future consideration

Stress Ratio Results for Multiple Load Cases

Show code check results for more than just the worst case. Should be able to see what the next worst, and next worse after that and so on. It's been over 10 years since I used it but I believe SACS does this. If so, could take a look at it.
about 2 years ago in STAAD.Pro 3 Future consideration

I sections with side plates

It is suggested to add I sections with side plates table under specifications user table manager tabs. Offshore brownfiled modificaitons work would involve adding side plates to existing I sections to increase its capacity.
over 1 year ago in STAAD.Pro 1 Needs review

OpenSTAAD function to extract the capacity of members

OpenSTAAD function to extract the capacity of members, so that it will be used for additional checks as per Code
about 2 years ago in STAAD.Pro 7 Future consideration

Rigid diaphragm on inclined floor/pitched floor/roof

Staad pro doesn't support for modelling of rigid diaphragm for inclined floor/inclined slab/inclined roof, so that response spectrum analysis can not be achieved in this case, so it is necessary to implement feature of modelling rigid diaphragm/se...
over 1 year ago in STAAD.Pro 1 Already exists

update to IBC 2021

No description provided
7 months ago in STAAD.Pro 2 Future consideration

Wind loading on cylindrical structures as per IS 1875 part 3

Provide a method to create wind loading on Cylindrical Structures as per Wind Pressure coefficients in clause 7.3.3.7 using Table 19 of IS 875 Part-3 2015
over 1 year ago in STAAD.Pro 4 Needs review