Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

STAAD.Pro

Showing 450

OpenSTAAD function to extract the capacity of members

OpenSTAAD function to extract the capacity of members, so that it will be used for additional checks as per Code
about 2 years ago in STAAD.Pro 7 Future consideration

OpenSTAAD Function to get CoG of the Model

It would be good to get a function in OpenSTAAD function to get the CoG of the Model.
about 1 year ago in STAAD.Pro 2 Needs review

I sections with side plates

It is suggested to add I sections with side plates table under specifications user table manager tabs. Offshore brownfiled modificaitons work would involve adding side plates to existing I sections to increase its capacity.
over 1 year ago in STAAD.Pro 1 Needs review

Add steel fireproofing specification to STAAD.pro Physical Modeler.

Currently, the only way to use STAAD.pro fireproofing specification is thru the Analytical Modeler. If you have a physical model, you have to break the connection and then edit the Input file to remove the "DO NOT EDIT" restrictions so that you ca...
7 months ago in STAAD.Pro 0 Needs review

Option/Command required to view failed RCC members.

I believe there is no option or command to directly view RC members that have failed, similar to that of "Utility" option available for checking failure of steel members. Failure of RC members must be manually checked from the "Analysis Output" op...
7 months ago in STAAD.Pro 0 Needs review

Rigid diaphragm on inclined floor/pitched floor/roof

Staad pro doesn't support for modelling of rigid diaphragm for inclined floor/inclined slab/inclined roof, so that response spectrum analysis can not be achieved in this case, so it is necessary to implement feature of modelling rigid diaphragm/se...
over 1 year ago in STAAD.Pro 1 Already exists

Wind loading on cylindrical structures as per IS 1875 part 3

Provide a method to create wind loading on Cylindrical Structures as per Wind Pressure coefficients in clause 7.3.3.7 using Table 19 of IS 875 Part-3 2015
over 1 year ago in STAAD.Pro 4 Needs review

SECTION DIAGRAM TO REPRESENT BUILT-UP WEB DEPTH ROUND VALUE

No description provided
7 months ago in STAAD.Pro 1 Needs review

Getting Ratio of the design calculation by OpenStaad API

There is no command to get the design calculation results in OpenStaad and I would like you to provide it.
over 2 years ago in STAAD.Pro 5 Future consideration

Hide Selected Object

it is a very useful option when you are trying to hide some selected entity for better view. HIDE SELECTED OBJECT rather than using invert Selection and other ways.
over 1 year ago in STAAD.Pro 1 Already exists