Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

STAAD.Pro

Showing 439

Request Omitted Data from IBC/ASCE7 Seismic Load Generator

There is no method, report, or output command available to display the "k" coefficient used by the program for vertical distribution of seismic base shear per ASCE 7-16, Eq 12.8-2. Since this value can vary with the period it needs to be reported ...
10 months ago in STAAD.Pro 1 Needs review

OpenSTAAD Function to Delete/Remove Existing Design Brief(s)

There exists a function to create a new design brief OSDesignUI::CreateDesingBrief(). However, there is no function to remove/delete existing design brief(s). Please review and consider adding this function.
over 1 year ago in STAAD.Pro 3 Future consideration

Add feature of modelling of chequered plates and grating in staad pro CE

In a multistorey steel structure, chequered plates and grating are widely used (as like slab used in RCDC) building, there is an option of modelling RCC slab in staad pro,like parametric modelling option,plate element option etc, but there isn't a...
over 1 year ago in STAAD.Pro 1 Already exists

Add Node Relative

I appreciate if future enhancement can take an option where you can add node relation to EXISTING in X, Y & Z direction. This option is available in some other software like ETABS where you just input X,Y &Z coordinate and click existing n...
over 1 year ago in STAAD.Pro 1 Already exists

Beam numbering in output file of RCDC

Beam FB111 is secondary beam and beam FB347 to FB350 is primary beam. We want beam numbering reverse. Primary beam should have one number and secondary beam should split into four different numbers. We don't want group name in output file.
10 months ago in STAAD.Pro 0 Needs review

OpenSTAAD Function to Redefine Member/Plate Incidence

There will be many occasions where a user wants to redefine the incidence of one or more members or plates. It would be helpful if there is an OpenSTAAD function to carry out this task as this saves a lot of effort and time. I understand that ther...
over 1 year ago in STAAD.Pro 3 Already exists

Reuse the water tank module to form a retaining wall module in SPPM

Are there any plans to use the Water Tank module in Structure Wizard in the Physical Modeler to create a retaining wall module? It seems like this could be developed easily from the water tank module.
over 2 years ago in STAAD.Pro 1 Needs review

Include some basic Sort functions & Search Functions in STAAD Results Table

Please could you incorporate some "basic functions" of Excel spreadsheet Tables into "STAAD Results table". This could be a row (with drop down tools) at the Top of the results tables. At the very least, just a few of these functions may help such...
over 1 year ago in STAAD.Pro 1 Future consideration

automatic generation of wind load

The automatic generation of wind load should be made available to Indian code also apart from American code. It will save lot of time in analysis and manual calculation.
over 4 years ago in STAAD.Pro 1 Already exists

OpenSTAAD function to remove the unused isotropic materials

Staad by default adds some materials to the model (please refer to the snapshot attached). Majority of these will not be used during automation (as the materials will be created separately based on the need) and hence the materials section remains...
almost 2 years ago in STAAD.Pro 1 Future consideration