Showing 362 of 426

Delete Pictures in v2023

No description provided
over 1 year ago in STAAD.Pro 1 Already exists

Turkish Seismic Code

Provide the Turkish Seismic Code (TBSC-2018) which was updated in 2018 for static seismic and response spectrum loading. Code attached.
over 1 year ago in STAAD.Pro 3 Future consideration

Printing joint forces in STAAD

A print command such as "PRINT JOINT FORCES LIST 1 2 3 etc." that would output all the member end forces at a specified node, for the specified load cases. This is currently possible using macros/openSTAAD, but would be very helpful if added to th...
over 1 year ago in STAAD.Pro 3 Will not implement

Automatic load generations (i.e. Wind Load or Seismic Load) to be used in the Reference Loads

Currently Automatic Wind/seismic Load cases can be generated in the Primary Load case only. Adding these in reference loads will give flexibility of applying different factors for different scenarios in basic load cases.
over 1 year ago in STAAD.Pro 1 Already exists

Capability in viewing steel design detail output as you could previously! V23

Evidently when performing steel design to Euro code (perhaps the same for other codes) you can only now see utilisation ratios. You no longer have the capability of seeing the detailed design results to check if your effective length or steel grad...
over 1 year ago in STAAD.Pro 1 Future consideration

Change reactions tab report

A current complaint. Please change the way reactions are shown in Reactions tab. Maybe as simple as leave the box just right next to the corresponding node, and not having them overlap in all the screen while moving and rotating. Just leave the an...
over 1 year ago in STAAD.Pro 1 Already exists

Postprocessing member design/revision without re-run analysis

Currently after run analysis we can see the status of design in postprocessing. If fail design appear, now we have to edit and rerun all model and check if edition is good or not. When only 5~10% of members fails, and in large models, this is very...
about 3 years ago in STAAD.Pro 1 Future consideration

implementation of design of double ISMB Box section profile while designing in code IS-800-2007-LSD.

When we are assigning ISMB 400*450 Box Section (Double Profile) while designing in Code IS-800-2007-LSD , Members are not able to design & Error coming. Kindly resolve the issue.
about 3 years ago in STAAD.Pro 1 Future consideration

Add Functionality to run a Direct Analysis following AISC 360 C.2a

Unless I am mistaken in order to run a direct analysis, you specify notional loads. However, per the specification it is allowable to use direct modeling of imperfections per C.2a. There is a way to specify camber and drift for members, but from w...
about 3 years ago in STAAD.Pro 1 Future consideration

Streamlining Workflow in STAAD.Pro: Reintroducing Shortcut Keys for Enhanced Analysis

Hello, In the previous version of STAAD V8i, there was a convenient shortcut key (F9) to run the analysis. However, it seems that this shortcut key has been removed in the advanced version, known as Connect Edition. To enhance the user experience ...
over 1 year ago in STAAD.Pro 1 Already exists