Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

STAAD.Pro

Showing 427

Add code checks for AISC 370

There is a new code for Stainless Steel that has been published by AISC. It would be nice to incorporate the code checks for AISC 370 for materials that have been selected as stainless steel.
almost 3 years ago in STAAD.Pro 10 Future consideration

Improve Curved Member Rendering and Analysis in STAAD.Pro

Executive Summary: This proposal outlines the need for enhancements to the rendering and analysis capabilities of curved members within the STAAD.Pro software. While curved members are essential for accurate modeling in various engineering applica...
6 months ago in STAAD.Pro 0 Needs review

Editor : Outlining - Collapse / Expand

Not sure if that's a glitch or an advantage; noticed that in STAAD.Pro 2024 version 24.00.02.354 while the collapse button only collapses, the expand button can both expand and collapse; so, may be we can have only one big button like the contents...
2 months ago in STAAD.Pro 2 Needs review

Open STAAD function for changing a existing tapper property

Please add one open STAAD function in which we can edit existing tapper property it will same much time
6 months ago in STAAD.Pro 1 Needs review

SOLIDITY RATIO IN STEEL STRUCTURE

Automation of solidity ratio of steel structure for calculating wing load shall be done. It is very time-consuming process for every structure design.
over 1 year ago in STAAD.Pro 7 Already exists

Cold formed Member design to EN 1993-1-3

Many STAAD users in Singapore and Malaysia have requested to implement the cold formed member design to EN 1993-1-3. We have lost some prospects to competitors because of the absence of this code in STAAD.Pro. This may be a feature that is request...
almost 3 years ago in STAAD.Pro 3 Future consideration

Auto load combination for IS 802 part 4

It will be better is auto load combination for following IS codes, IS 802 Part 1/Sec1 2015 - Clause 13 - For Transmission tower Design IS 802 Part 4 2023 - Clause 13 - For latticed switchyard structure Design As of now only design code of IS 802 i...
4 months ago in STAAD.Pro 0 Needs review

Cold form section outside the standard library not designed in STAADpro as per IS801

STAADpro is not able to design cold form section outside the standard library or any user defined cold form section as per IS801. This is severe limitation as many users are using sections of their choice which are not in the library. This is espe...
2 months ago in STAAD.Pro 1 Future consideration

Design of double channel section in STAAD needs improvement

At present design of double channel in STAAD as per IS800 LSD is having certain work flow. It assumes higher MI as a major axis even if it can be about minor axis Y which is not correct. STAAD should consider section orientation as provided by use...
2 months ago in STAAD.Pro 1 Already exists

Design of double I section as column is required.

In most of the industrial sheds, double I section spaced apart is used as crane column and single I section is used to support the roof above. In present STAADpro ver 24 facility to design double I section as per IS800 LSD is not available . This ...
2 months ago in STAAD.Pro 1 Needs review