include MERGE NODE, CONNECT BEAMS & COLLINEAR BEAMS under Node Tools

it might also be helpful, if we can add the MERGE NODE tool in the "popup" Node tools when many nodes are selected (just like MERGE BEAM tool is included in the "popup" Beam tools) and the CONNECT BEAMS and COLLINEAR BEAMS tool also (to generate b...
almost 2 years ago in STAAD.Pro 1 Future consideration

Auto Wind load for roofing

Implement a method to generate loading on roof structures as per the IS 875 part 3 wind load code using the Cpe method using the values in Table 8 / 9
almost 3 years ago in STAAD.Pro 6 Future consideration

Warning based on superceded (old) code appears in Seismic analysis using IS 1893 pt 1.

STAAD Pro CONNECT Edition shows a warning based on IS 1893 part 1:2002, when the latest code available currently under use is IS 1893 part 1:2016. Kindly clarify why should warnings based on old codes appear when the user has specifically selected...
3 months ago in STAAD.Pro 0 Needs review

5% accidental eccentricity as per Eurocode 1998:2004, using response spectra method

The accidental eccentricity in staad pro. as per Eurocode 1998:2004, while analyzing the structure for seismic loads using response spectra method.
10 months ago in STAAD.Pro 1 Future consideration

Steel Check Code for all code, please make it uniform format

ANL file for steel code has changed format can you revert back again or atleast put to option on Track command to retain original format.
3 months ago in STAAD.Pro 0 Needs review

Make Staad Multi Processor (Multi-Threaded)

This would cut down the analysis time required by STAAD significantly. If it is too much work to change the solver code to benefit from multi-threads, can at least each basic load or each load combination be run at a different thread? There's no r...
over 2 years ago in STAAD.Pro 1 Future consideration

In wind load generator, please incorporate wind load in other directions such as X & Z. Also, wind load on roof truss & corners needs to be incorporated.

There is no way to add wind load in other direction in case of unclad building. For example : - staad taking load case only in one direction i.e. +X, whenever I try to add another case in z direction, previous case gets deleted automatically. So, ...
almost 2 years ago in STAAD.Pro 3 Future consideration

Add steel fireproofing specification to STAAD.pro Physical Modeler.

Currently, the only way to use STAAD.pro fireproofing specification is thru the Analytical Modeler. If you have a physical model, you have to break the connection and then edit the Input file to remove the "DO NOT EDIT" restrictions so that you ca...
3 months ago in STAAD.Pro 0 Needs review

Integration OpenSTAAD with python

I consider that the way of using openstaad with VBA is somewhat tedious due to the characteristics of that programming language, therefore, my idea is to propose an openstaad repository but focused on python, which, in my opinion, would facilitate...
10 months ago in STAAD.Pro 1 Already exists

Option/Command required to view failed RCC members.

I believe there is no option or command to directly view RC members that have failed, similar to that of "Utility" option available for checking failure of steel members. Failure of RC members must be manually checked from the "Analysis Output" op...
3 months ago in STAAD.Pro 0 Needs review