Providing a Steel Box section by Tube option in User provided table

For Providing a Steel Box section with different Flange and web thickness , we have to make the section in Section Wizard which is time consuming during Optimization and also 3D visualisation is not there. If the feature similar to Tube in User pr...
about 20 hours ago in STAAD.Pro 0 Needs review

Beam local axis symbol, scaling

After being introduced to StaadPRO, the one fundamental thing that I can't believe is not implemented is scaling of local beam axis symbols. It's at times almost impossible to find out the local axis of the beams in the graphic area, and this is v...
1 day ago in STAAD.Pro 0 Needs review

Implementation of IS18168 for steel design in STAAD Pro

Latest code released in 2023 for designing of steel members is STILL not available in STAAD.Pro. This has already been implemented in MIDAS.
4 months ago in STAAD.Pro 0 Needs review

Request to Correct Default Seismic Zone Factor for Cuddalore, Tamilnadu, India in STAAD.Pro as per IS 1893 - Part 1 - 2016

Hello STAAD.Pro Team, While generating Seismic Definitions, the software automatically assigns the Zone Factor for Cuddalore, Tamilnadu, India as 0.16. This value is not aligned with local seismic requirements and also with IS 1893 - Part 1 - 2016...
5 days ago in STAAD.Pro 0 Needs review

ENABLE DESIGN MODELING FOR CORRUGATED STEEL DECK DIAPHRAGMS

Section 12.3 of ASCE 7 - 22 states that unless a diaphragm can be idealized as either flexible or rigid, structural analysis should explicitly include consideration of the stiffness of the diaphragm (i.e. semirigid modeling). I am publishing an ar...
11 days ago in STAAD.Pro 0 Needs review

Drift Parameters in Russian Steel Codes

If there is no particular reason why the Russian steel design codes(SP 16.13330) do not provide parameters for drift verification (such as CAN in AISC), I would like to formally request that they be added.
9 days ago in STAAD.Pro 4 Will not implement

Particular Cases for Validation and Calculation of Ly and Lz Lengths in STAAD.Pro

We have noticed that, under certain configurations, the “Effective Length Calculator” tool in STAAD.Pro may yield results that are not conservative, which poses a risk to the structural safety of the project. Allowing users to validate and manuall...
3 months ago in STAAD.Pro 1 Future consideration

Implementation of Export to .docx with Native Word Tables

Details: Generation of Native Tables: STAAD.Pro Advance should create tables using Microsoft Word's internal structure. Basic Format Maintenance: Maintain borders and initial alignment to facilitate identification, prioritizing editability. Text N...
4 months ago in STAAD.Pro 0 Needs review

Automatic Linking of Connections in Connection Designer with Steel AutoDrafter

I would like to suggest a significant improvement to the software. Currently, marking each connection one by one in engineering drawings is time-consuming and prone to errors. It would be extremely useful to link the connections generated in Conne...
6 months ago in STAAD.Pro 2 Future consideration

Provide option to Rename the Group

Sometimes, during the initial stages, we may assign a group name—say, XYZ—but later someone might want to change that group name. There should be an option to rename the group without opening the STAAD editor file.
12 days ago in STAAD.Pro 1 Future consideration