RAM DOES NOT SUPPORT TO ADD STIFFENER TO PINNED BASE PLATE?

It is hoped that the method of adding stiffeners in the design of American standard column bases can be increased, and it is best to be customizable. For example, extending plate stiffeners can be set on the web of the I-beam.
4 months ago in STAAD.Pro 0 Needs review

In wind load generator, please incorporate wind load in other directions such as X & Z. Also, wind load on roof truss & corners needs to be incorporated.

There is no way to add wind load in other direction in case of unclad building. For example : - staad taking load case only in one direction i.e. +X, whenever I try to add another case in z direction, previous case gets deleted automatically. So, ...
about 2 years ago in STAAD.Pro 3 Future consideration

Direct Analysis Method with Tension-Only members

Just as the title. To be able to analyze a structure with Tension-Only members using the Direct Analysis Method.
over 2 years ago in STAAD.Pro 1 Future consideration

Connections design using angle & channel connections should be added in ram connection

Connections design using angle & channel connections should be added in ram connection
4 months ago in STAAD.Pro 0 Needs review

when standard sections are used instead of legacy analysis cant be imported to RCDC

In the new staad edition standard sections were added in addition to legacy.but when standard scetions were used, the analysis file cant be imported to RCDC.please solve this as there are new standard sections added which are not available in legacy.
4 months ago in STAAD.Pro 0 Needs review

Moving Loads Acting in Horizontal Directions

Provide the ability to have horizontal moving loads in addition to the vertical loads. For example, ASCE 7 requires cranes to be designed for vertical loads and horizontal loads. It would be great if STAAD had the ability to have both the vertical...
over 2 years ago in STAAD.Pro 3 Future consideration

Combined profile of a wide flange and channel as a single object

For Inclusion of built up section in standard I section combination with Channel section on top flange, which is widely used for gantry girder.
about 2 years ago in STAAD.Pro 5 Already exists

Aluminium design checks per BS EN 1999

Eurocode checks for aluminium members
4 months ago in STAAD.Pro 0 Needs review

Slab deflection plots

Currently the only way to check the deflection of a slab is to review the deflected shape of the shells' mesh, or in the tabulated results. It would be very useful if the contour plots for shells included the option to contour deflections as well ...
over 1 year ago in STAAD.Pro 2 Future consideration

Steel AutoDrafter: Customized Offset Distance

Steel Auto-Drafter draws member releases with a 20mm offset by default. The user would like to set this offset distance to an arbitrary distance. Additionally, the user would like to set separate distances for each of the following members: ...