Auto Wind load for roofing

Implement a method to generate loading on roof structures as per the IS 875 part 3 wind load code using the Cpe method using the values in Table 8 / 9
almost 3 years ago in STAAD.Pro 6 Future consideration

RCDC design all type footing

make RCDC design all type footing(single,combine,mat......)combine (RCDC,RCDC FE and staad advance foundation)
over 3 years ago in STAAD Concrete 1 Needs review

5% accidental eccentricity as per Eurocode 1998:2004, using response spectra method

The accidental eccentricity in staad pro. as per Eurocode 1998:2004, while analyzing the structure for seismic loads using response spectra method.
10 months ago in STAAD.Pro 1 Future consideration

Make Staad Multi Processor (Multi-Threaded)

This would cut down the analysis time required by STAAD significantly. If it is too much work to change the solver code to benefit from multi-threads, can at least each basic load or each load combination be run at a different thread? There's no r...
over 2 years ago in STAAD.Pro 1 Future consideration

Warning based on superceded (old) code appears in Seismic analysis using IS 1893 pt 1.

STAAD Pro CONNECT Edition shows a warning based on IS 1893 part 1:2002, when the latest code available currently under use is IS 1893 part 1:2016. Kindly clarify why should warnings based on old codes appear when the user has specifically selected...
3 months ago in STAAD.Pro 0 Needs review

SFA Foundation use uniform (average) Effective Bearing Pressure per AASHTO 10.6.1.4

Currently, SFA uses the highest corner pressure to design the foundation size bearing on soil. Please revise the SFA program to have an option for a soil supported foundation (versus a rock supported foundation) and provide revised foundation sizi...
almost 2 years ago in STAAD Concrete 2 Needs review

Steel Check Code for all code, please make it uniform format

ANL file for steel code has changed format can you revert back again or atleast put to option on Track command to retain original format.
3 months ago in STAAD.Pro 0 Needs review

In wind load generator, please incorporate wind load in other directions such as X & Z. Also, wind load on roof truss & corners needs to be incorporated.

There is no way to add wind load in other direction in case of unclad building. For example : - staad taking load case only in one direction i.e. +X, whenever I try to add another case in z direction, previous case gets deleted automatically. So, ...
almost 2 years ago in STAAD.Pro 3 Future consideration

COMBINED FOOTING, RAFT FOOTING IN RCDC

May you please include the design of raft foundation and combined footing in RCDC
over 4 years ago in STAAD Concrete 1 Needs review

Auto wind load generation for roof/purlins..

Frequently used for design of all steel structure with shed/roof CONCERN CODE(ALL) especially IS 875 part 3: 1-Sir, staad CE has support the auto wind load as for clad/unclad buildings, this wind load is applied on the surfaces/periphery of buildi...
almost 3 years ago in STAAD.Pro 4 Future consideration