AutoDrafter - Allow Isometric View (Full MTO Table)

It is only possible to create a plan/section by selecting a member at that location, and must be in the plane of either a plan or section. MTO take-off "drawing" only shows table - a great addition would be to add the isometric view of the structu...
3 months ago in STAAD.Pro 0 Needs review

AutoDrafter - Allow Turn On/Off Layers

Some layers in autodrafter clog up the view of the drawing (e.g., member centerlines). It would be great if layers can be turned on/off within AutoDrafter Drawing Style Manager.
3 months ago in STAAD.Pro 0 Needs review

RCDC - Update Water Tank workflow using ACI code

Currently, water tank design is only available for the Euro Code. Please update for use with current ACI code.
10 months ago in STAAD Concrete 1 Needs review

NSCP 2022 Philippines Seismic Load(similar to ASCE 7-10) addition

Requesting to add NSCP 2022 Philippines Seismic Load(similar to ASCE 7-10) addition to STAAD.Pro. Xstructures can provide all formula and technical documentation
over 1 year ago in STAAD.Pro 4 Future consideration

Capacity Design as per NZS3404

Currently STAAD is performing only geometrical check of the members in accordance with Chapter 12 of NZS 3404. However, no design is performed based on the capacity design principles provided in this Chapter. As industries in New Zealand is increa...
21 days ago in STAAD.Pro 0 Needs review

Update EN 1993-1-1 design code

Currently, EN 1993-1-1 provide in STAAD.Pro is 2005 edition. My request is to update the code to the latest edition, 2023.
2 months ago in STAAD.Pro 2 Future consideration

Modelling and Design of tapered channel

I Need to design lot of platforms with cantilever beams. Tapered channel is easy to fabricate in plate and most economical section for cantilever conditions. Hence I request you to include this options in the staad. Moreover, tapered I is already ...
2 months ago in STAAD.Pro 3 Needs review

Can we transfer maximum thermal load ( thermal 1, thermal 2, thermal 3) from autoPIPE pipelink to STAAD.Pro.

No description provided
23 days ago in STAAD.Pro 0 Needs review

E-tabs - Require facility to read one or more floors (group) for only beam design and slab design without data of full model.

No description provided
27 days ago in STAAD Concrete 0 Needs review

Inclusion of updated IS code IS 1893 (part 4):2024 for design of steel structures

Changes in seismic design parameters or changes in class of Industrial structures in new code will lead to changes in seismic forces experienced by the structure. This may lead to different results than the one obtained from the old code (2015 ver...