Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

STAAD.Pro

Showing 445 of 551

Can we transfer maximum thermal load ( thermal 1, thermal 2, thermal 3) from autoPIPE pipelink to STAAD.Pro.

No description provided
3 months ago in STAAD.Pro 0 Needs review

EN1993-1-1 Eurocode 3 2005

STAAD.Pro- software is using EN1993-1-1 Eurocode 3 2005, - this is not the latest version of this design code. How do we go about updating this in STAAD-Pro ? We need to be using the latest design code for compliance with our EN1090 fabrication wo...
over 1 year ago in STAAD.Pro 1 Future consideration

Make Staad Multi Processor (Multi-Threaded)

This would cut down the analysis time required by STAAD significantly. If it is too much work to change the solver code to benefit from multi-threads, can at least each basic load or each load combination be run at a different thread? There's no r...
almost 3 years ago in STAAD.Pro 1 Future consideration

Verification of User-Defined Steel Reinforcement

Good morning. It would be helpful if future versions included the option for the user to define the reinforcement layout, allowing STAAD Foundation Advanced to verify it — both for pedestals and foundations
4 months ago in STAAD.Pro 0 Needs review

Auto wind load generation for roof/purlins..

Frequently used for design of all steel structure with shed/roof CONCERN CODE(ALL) especially IS 875 part 3: 1-Sir, staad CE has support the auto wind load as for clad/unclad buildings, this wind load is applied on the surfaces/periphery of buildi...
about 3 years ago in STAAD.Pro 4 Future consideration

Calculate section properties when adding new shape to database

Two things here:Have the ability for STAAD (in the physical modeler) to calculate the section properties when entering a new shape into an existing database. For example, I'm adding a new hat channel into the AISI cold formed Profiles database. In...
about 3 years ago in STAAD.Pro 4 Future consideration

CANADA/NRC seismic code 2023

Presently Staad pro is using CANADA/NRC seismic code 2010, but available code is 20213 , kindly update your Staad soft ware accordingly, to perform our Canadian client asap
4 months ago in STAAD.Pro 0 Needs review

In wind load generator, please incorporate wind load in other directions such as X & Z. Also, wind load on roof truss & corners needs to be incorporated.

There is no way to add wind load in other direction in case of unclad building. For example : - staad taking load case only in one direction i.e. +X, whenever I try to add another case in z direction, previous case gets deleted automatically. So, ...
about 2 years ago in STAAD.Pro 3 Future consideration

Untie the Section Name in the Properties window from the Base Unit settings

The proposed enhacement would allow the units that are being used in the model to appear correctly and complete in the Section Name window, and also in the reports because, for example, being tied as they are now only allows units to be presented ...
4 months ago in STAAD.Pro 0 Needs review

Direct Analysis Method with Tension-Only members

Just as the title. To be able to analyze a structure with Tension-Only members using the Direct Analysis Method.
about 2 years ago in STAAD.Pro 1 Future consideration