Auto Wind load for roofing

Implement a method to generate loading on roof structures as per the IS 875 part 3 wind load code using the Cpe method using the values in Table 8 / 9
about 3 years ago in STAAD.Pro 6 Future consideration

State the code basis for utilization ratio tables in reports

In STAAD 2023, if a report is created and the Utilization Ratio table is included, a critical Clause is listed for each member. However, there is no indication in/above the table of which code, or code version, that the Clause pertains to. Please ...
about 1 year ago in STAAD.Pro 2 Future consideration

Analysis & Design option for Self supporting roofing sheet recommended by RDSO , GOI .........Proflex company MNC is majorly manufacturing those roofing sheets........

Analysis & Design option for Self supporting roofing sheet recommended by RDSO , GOI .........Proflex company MNC is majorly manufacturing those roofing sheets........ The irregular shape of sheet is difficult to model & analyse in staad p...
4 months ago in STAAD.Pro 0 Needs review

Help and Users Manual of Japanese Language in Staad Pro

Let me request to provide the help and Users Manual of Japanese language in Staad pro. Currently It is not existing. So Japanese user cannot use Staad pro as the Calculation Note for Architectural application to Japanese government. If there is it...
4 months ago in STAAD.Pro 1 Planned

UNT UNB PARAMETER FOR IS 800

STAAD currently has only LX and LY parameters but does not have separate parameters for cases where a beam has only the top flange restrained or only the bottom flange restrained. It would be useful if both were separated.
4 months ago in STAAD.Pro 0 Needs review

Convert beams to shells for FEA

It would be great to be able to mesh a STAAD stick model using the assigned profiles (i.e. having the software replace the beam with a set of plates to match the flange/web sizes and thicknesses) in order to do some high level finite element analy...
11 months ago in STAAD.Pro 3 Needs review

Make Staad Multi Processor (Multi-Threaded)

This would cut down the analysis time required by STAAD significantly. If it is too much work to change the solver code to benefit from multi-threads, can at least each basic load or each load combination be run at a different thread? There's no r...
almost 3 years ago in STAAD.Pro 1 Future consideration

EN1993-1-1 Eurocode 3 2005

STAAD.Pro- software is using EN1993-1-1 Eurocode 3 2005, - this is not the latest version of this design code. How do we go about updating this in STAAD-Pro ? We need to be using the latest design code for compliance with our EN1090 fabrication wo...
over 1 year ago in STAAD.Pro 1 Future consideration

Auto wind load generation for roof/purlins..

Frequently used for design of all steel structure with shed/roof CONCERN CODE(ALL) especially IS 875 part 3: 1-Sir, staad CE has support the auto wind load as for clad/unclad buildings, this wind load is applied on the surfaces/periphery of buildi...
about 3 years ago in STAAD.Pro 4 Future consideration

RAM DOES NOT SUPPORT TO ADD STIFFENER TO PINNED BASE PLATE?

It is hoped that the method of adding stiffeners in the design of American standard column bases can be increased, and it is best to be customizable. For example, extending plate stiffeners can be set on the web of the I-beam.
4 months ago in STAAD.Pro 0 Needs review