Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

STAAD.Pro

Showing 439

Steel Check Code for all code, please make it uniform format

ANL file for steel code has changed format can you revert back again or atleast put to option on Track command to retain original format.
4 months ago in STAAD.Pro 0 Needs review

Wind Loads on Steel Structures

I think the wind load application should be rewritten to make it simpler and more user friendly. STAAD is at least three times as long as SAP2000 when inputting wind loads.
about 2 years ago in STAAD.Pro 12 Needs review

Add grid lines

Grid lines are already included when using Auto Drafter. That idea could be very useful in GUI.
about 2 years ago in STAAD.Pro 3 Future consideration

Add steel fireproofing specification to STAAD.pro Physical Modeler.

Currently, the only way to use STAAD.pro fireproofing specification is thru the Analytical Modeler. If you have a physical model, you have to break the connection and then edit the Input file to remove the "DO NOT EDIT" restrictions so that you ca...
4 months ago in STAAD.Pro 0 Needs review

Moving Load Moving in Global Vertical Direction

The ability to apply horizontal moving loads that move in the vertical direction (up a column) (e.g. elevator loads on a column).
over 2 years ago in STAAD.Pro 3 Future consideration

Option/Command required to view failed RCC members.

I believe there is no option or command to directly view RC members that have failed, similar to that of "Utility" option available for checking failure of steel members. Failure of RC members must be manually checked from the "Analysis Output" op...
4 months ago in STAAD.Pro 0 Needs review

Beam utilization listing with drop down box

The "actual ratio" button in postprocessing mode is not working for a lot of users in Subsea7. This button is supposed to re-arrange beam utilizations from default beam number order, to utilization ascending order, and is very helpful. The problem...
9 months ago in STAAD.Pro 2 Needs review

SECTION DIAGRAM TO REPRESENT BUILT-UP WEB DEPTH ROUND VALUE

No description provided
4 months ago in STAAD.Pro 1 Needs review

Time History in multiple load case for blast loads

For Blast loads in some cases we have to apply blast load in all the direction i.e x and z in different load cases. presently the time history load is possible only in one load case. Time history should be allowed to be added in mutiple load cases
over 1 year ago in STAAD.Pro 3 Future consideration

Update ASCE7 to the latest version 7-22

Currently, ASCE7-22 is not available in STAAD. Pro. Wind and Seismic load generation with this code is required for our project execution.
about 2 years ago in STAAD.Pro 1 Future consideration