Add NZS 1170.5 code to Seismic Codes in STAAD

STAAD does not have NZS 1170.5 in its Seismic Codes. Users in ANZ uses custom spectrum and factored it up to match the base shear. Adding this code will help the users in ANZ work directly with the NZ code and thus speed up their productivity. Use...
almost 3 years ago in STAAD.Pro 1 Future consideration

Add steel fireproofing specification to STAAD.pro Physical Modeler.

Currently, the only way to use STAAD.pro fireproofing specification is thru the Analytical Modeler. If you have a physical model, you have to break the connection and then edit the Input file to remove the "DO NOT EDIT" restrictions so that you ca...
6 months ago in STAAD.Pro 0 Needs review

Include the moving load possibility in physical model

No description provided
over 1 year ago in STAAD.Pro 3 Needs review

Option/Command required to view failed RCC members.

I believe there is no option or command to directly view RC members that have failed, similar to that of "Utility" option available for checking failure of steel members. Failure of RC members must be manually checked from the "Analysis Output" op...
6 months ago in STAAD.Pro 0 Needs review

Eurocode Wind Load Automatic Generation

Please add the ability to automatically generate wind loading to eurocodes.
about 2 years ago in STAAD.Pro 1 Future consideration

Waffle /Grid slab and flat slab

Heavy loaded structures...
about 3 years ago in STAAD.Pro 3 Future consideration

SECTION DIAGRAM TO REPRESENT BUILT-UP WEB DEPTH ROUND VALUE

No description provided
6 months ago in STAAD.Pro 1 Needs review

OpenSTAAD function to extract the Beam Forces summary table for the selected beams

Hi, Typically, to get end forces to design the connection for a certain beam size, a group is created and the bounding beam forces for the group are extracted using the "Beam Results - Beam Forces - Summary table" using the "Results Setup - Range ...
over 1 year ago in STAAD.Pro 1 Future consideration

Do not Auto split the design parameter & loadings.

When dealing with a substantial number of members within a STAAD model, the design parameters tend to split automatically. Consequently, this automatic splitting poses challenges when attempting to review the design parameters. The same situation ...
about 2 years ago in STAAD.Pro 1 Future consideration

ASEC7 vertical structural irregularities check

The STAAD.Pro now can not check the the vertical structural irregularities 5a/5b in the ASCE 7 table 12.3-2 by ant command stream, but as the code demand, the designer need check this irregularities, it is very difficult and cost time for designer...