Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

STAAD.Pro

Showing 456

WIND CORNER PRESSURE AND ROOF IN WIND LOAD GENERATOR

Hello i would like to drop my suggestion for consideration, as we know up to now Wind Load generator, can only generate wind on panels. But during design we may have to apply corner wind pressure especially in connection design and also to apply w...
over 2 years ago in STAAD.Pro 2 Needs review

Stress Ratio Results for Multiple Load Cases

Show code check results for more than just the worst case. Should be able to see what the next worst, and next worse after that and so on. It's been over 10 years since I used it but I believe SACS does this. If so, could take a look at it.
about 2 years ago in STAAD.Pro 3 Future consideration

OpenSTAAD function to extract plate corner stresses.

Anyone who perform post-processing/detailed analysis on plated structures will benefit from this. The function could take a plate ID and loadcase as input, and give plate corner stresses for all corners as output.
about 2 years ago in STAAD.Pro 1 Already exists

Canadian Seismic Load per 2015 NBC code parameters

Would like to get implemented NBC 2015 Code parameter.
over 1 year ago in STAAD.Pro 0 Future consideration

OpenSTAAD function to extract the capacity of members

OpenSTAAD function to extract the capacity of members, so that it will be used for additional checks as per Code
about 2 years ago in STAAD.Pro 7 Future consideration

ASEC7 vertical structural irregularities check

The STAAD.Pro now can not check the the vertical structural irregularities 5a/5b in the ASCE 7 table 12.3-2 by ant command stream, but as the code demand, the designer need check this irregularities, it is very difficult and cost time for designer...
about 1 year ago in STAAD.Pro 1 Needs review

I sections with side plates

It is suggested to add I sections with side plates table under specifications user table manager tabs. Offshore brownfiled modificaitons work would involve adding side plates to existing I sections to increase its capacity.
over 1 year ago in STAAD.Pro 1 Needs review

OpenSTAAD Function to get CoG of the Model

It would be good to get a function in OpenSTAAD function to get the CoG of the Model.
about 1 year ago in STAAD.Pro 2 Needs review

Warning based on superceded (old) code appears in Seismic analysis using IS 1893 pt 1.

STAAD Pro CONNECT Edition shows a warning based on IS 1893 part 1:2002, when the latest code available currently under use is IS 1893 part 1:2016. Kindly clarify why should warnings based on old codes appear when the user has specifically selected...
7 months ago in STAAD.Pro 0 Needs review

Rigid diaphragm on inclined floor/pitched floor/roof

Staad pro doesn't support for modelling of rigid diaphragm for inclined floor/inclined slab/inclined roof, so that response spectrum analysis can not be achieved in this case, so it is necessary to implement feature of modelling rigid diaphragm/se...
over 1 year ago in STAAD.Pro 1 Already exists