Ability to Revert to Old Report Format within Staad
The new report formatting while nice in appearance is cumbersome, not quick to use and has issues with savings....can't there be an ability for staad users to "revert" back to the old school report formatting?
I chose this "add idea" route because I couldn't find another channel to communicate my disappointment as stated below. Report setup in STAAD. Pro 2024 is not good. It gives poor quality picture compared to previous versions. This kind of weird pr...
OpenSTAAD function to extract plate corner stresses.
Anyone who perform post-processing/detailed analysis on plated structures will benefit from this. The function could take a plate ID and loadcase as input, and give plate corner stresses for all corners as output.
Postprocessing display of multiple design blocks for AIJ codes
Currently, it is possible to display results for multiple design blocks with AISC360-16 results only.
This feature is also required for AIJ2005 and 2002.
In AIJ codes, load cases are classified into parmanent loads, temporary loads and loads for...
about 2 years ago
in STAAD.Pro
1
Future consideration
Non linear time history analysis still not implemented in staad pro for different types of structure like residential, industrial structure etc, kindly add non linear time history analysis in staad CE as it gives realistic and more conservative an...
almost 3 years ago
in STAAD.Pro
2
Future consideration
Insert node in members having built-up I-Section property.
Hi, When inserting a node into a beam having a tapered I-section property, the software automatically generates the properties for the new section and places it at the end of the property section. This poses significant challenges during the optim...
about 2 years ago
in STAAD.Pro
3
Future consideration
Connection Workflow calculation report include input parameters
for site engineer ,it is useful to understand calculation report.as input parameters added in the calculation report, it is benefit for checker to review. eg. beam section ,column section ,steel strengh ect.
JIS/TIS c-light lip section database for coldform steel design
Too many requirement for design the JIS/TIS c-light lip section as cold formed steel using STAAD. So, is it possible to have an JIS/TIS c-light lip section properties included in the database. If there are these section database in STAAD, it's can...
about 2 years ago
in STAAD.Pro
1
Future consideration
It will be very helpful for the estimation if PRINT CG command works for groups of plate and beams and solid also. This will give directly the weight and volume of certain part of model, which is most of the the basic parameter of optimization. Ri...
almost 3 years ago
in STAAD.Pro
3