Beam utilization listing with drop down box

The "actual ratio" button in postprocessing mode is not working for a lot of users in Subsea7. This button is supposed to re-arrange beam utilizations from default beam number order, to utilization ascending order, and is very helpful. The problem...
3 months ago in STAAD.Pro 2 Needs review

Added functionality of new Effective Length Calculator

I am liking this new calculator it super cool. But I have two ideas to build on it 1) The training video that Bentley created to demonstrate this calculator had the demonstrator use the calculator and then open up the input file to delete out the ...
12 months ago in STAAD.Pro 3 Future consideration

Connection Workflow calculation report include input parameters

for site engineer ,it is useful to understand calculation report.as input parameters added in the calculation report, it is benefit for checker to review. eg. beam section ,column section ,steel strengh ect.
about 2 months ago in STAAD.Pro 2 Already exists

5% accidental eccentricity as per Eurocode 1998:2004, using response spectra method

The accidental eccentricity in staad pro. as per Eurocode 1998:2004, while analyzing the structure for seismic loads using response spectra method.
5 months ago in STAAD.Pro 1 Future consideration

SOLIDITY RATIO IN STEEL STRUCTURE

Automation of solidity ratio of steel structure for calculating wing load shall be done. It is very time-consuming process for every structure design.
over 1 year ago in STAAD.Pro 7 Already exists

Section Diagram to represent Web thickness as old STAAD pro versions

easy way to find the section properties . Also all the flange width and thickness and web depth is coming except web thickness
about 2 months ago in STAAD.Pro 1 Already exists

Inclusion of SS EN 1998-1 Seismic Action & Accidental Torsion

Application of seismic action (including accidental torsion) for structure in Singapore using EN 1998-1 is cumbersome. Request to include this code in future development.
3 months ago in STAAD.Pro 2 Needs review

AISC 341-16/22 Connection Design code support

Connection Design Part in Staad.Pro now only support AISC 341-05, but as we know the latest edition of AISC 341 is AISC 341-16/22 .Althouth the ram connection can support AISC 341-16/22, but it need the designer to add every load case datas to the...
5 months ago in STAAD.Pro 1 Planned

Automatically generate Image Reports

Please add an option to generate an image report for every load case. The image report are showing how the forces are affecting the structure (see attached screenshots). Currently it is only possible to manually create a screenshot for each load c...
about 2 years ago in STAAD.Pro 1 Needs review

Add code checks for AISC 370

There is a new code for Stainless Steel that has been published by AISC. It would be nice to incorporate the code checks for AISC 370 for materials that have been selected as stainless steel.
over 2 years ago in STAAD.Pro 10 Future consideration