Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

STAAD.Pro

Showing 406

STEEL ROD AS BRACING IN STAAD PRO CONNECT EDITION

I have model my truss and i want to add steel rod of 20mm diameter as a bracing on pipes carrying the truss, is this option available in Staad Pro Connect Edition?
over 4 years ago in STAAD.Pro 1 Already exists

FLAT SLAB, WITHOUT BEAMS

Option for modelling, analysis and design of a project with flat slab should be added in Staad Pro Connect Edition
over 4 years ago in STAAD.Pro 1 Already exists

Creation of Grid system & creation of views by Grid mark nos

I would suggest to add Grid system at column bases and also create floor levels. This would help us to isolate the grid views & floor levels during the time of geometric modelling.
over 4 years ago in STAAD.Pro 3 Already exists

Inserting nodes on the curved beam should be made available.

Inserting node on the curved beam should be made available. Currently, it is not avialble . we have import the auto cad DXF to go ahead
over 4 years ago in STAAD.Pro 1 Future consideration

Design wide flange with cover plates to EN1993-1

Currently design of I plate with cover plates are not yet implemented in Euro code for STAAD. This idea is to add support for this capability.
about 2 years ago in STAAD.Pro 1 Future consideration

Load Group display in Physical Modeler

Load Group (as reference load) in Physical Modeler should show all loads of same category in a single spreadsheet instead of separate spreadsheet similar to analytical reference load
about 2 years ago in STAAD.Pro 1 Needs review

PARAMETRIC MODEL WAFFLE AND RIBBED SLAB

I suggest in parametric model, waffle and ribbed slab option to be added
over 2 years ago in STAAD.Pro 1 Needs review

section detail backup

every time when we update software, it should be notified to take necessary backup of added section for cold form, it is really painful doing same work in 1-2 month while software is being updated. it will save designerr time
over 2 years ago in STAAD.Pro 1 Future consideration

Latest Australian steel design code

Need latest Australian code- AS 4100- 2020 and As 3600-2018 to be implemented in staad urgently for our project execution.
over 2 years ago in STAAD.Pro 3 Future consideration

Seismic load generation - Australian Code

The seismic load generation facility as per Australian code (AS 1170.4) is missing in STAAD.Pro. As such users working on projects in the Australian region will greatly benefit if this facility is included in the program.
over 2 years ago in STAAD.Pro 1 Future consideration