Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

STAAD Concrete

Showing 93

automated deflection check for concrete

No description provided
9 months ago in STAAD Concrete 4 Needs review

RCDC DESIGN OF COLUMN INCLINED AT AN ANGLE.

I would like to suggest the addition of column designs that are inclined at an angle. You may find a project having many columns inclined at a certain angle; it will consume a lot of time to design them manually, as RCDC is not capable of designin...
6 months ago in STAAD Concrete 1 Needs review

RCDC DESIGN OF BEAM INCLINED AT AN ANGLE.

Hello i would suggest STAAD and RCDC to implement design of beams which are inclined at angle to meet project requirements.
6 months ago in STAAD Concrete 0 Needs review

Beam - edit reinf for grouped beam - issue

This issue exists in all design codes.beams without grouping, edit reinforcement works properly. if beams are grouped, software unable to change the reinforcement.for grouped beams, quick detail and copy paste reinforcement works fine. Service cas...
3 months ago in STAAD Concrete 0 Needs review

Combined wall design taking more time for specific case

refer Service case Service Case 1494311: [CS0270621] Combined wall design taking more timeAs alternate solution is available, it is marked as Low severity.
3 months ago in STAAD Concrete 0 Needs review

Beam - edit reinf for grouped beam - issue

This issue exists in all design codes.beams without grouping, edit reinforcement works properly. if beams are grouped, software unable to change the reinforcement.for grouped beams, quick detail and copy paste reinforcement works fine. Service cas...
3 months ago in STAAD Concrete 0 Needs review

Beam - Biaxial - Reinforcement Modified through quick detail no reflected in report

following issues are identified, program goes on non-responding mode using Quick detail tool. reinforcement changed using copy paste reinforcement tool is not reflected in the design calculation report. client file is of older version (11.03.01.10...
3 months ago in STAAD Concrete 0 Needs review

Footing design - Enhancement related to Sliding and Uplift check

refer Service case Service Case 1441906: [CS0222209] Calculation basis for buoyancy and sliding check of pad footingsif the soil and self -weight is calculated with effect of buoyancy then there is no need to deduct it again to calculate net downw...
3 months ago in STAAD Concrete 0 Needs review

Beam design - Ductile detailing - failure case is not handled if diameter is restricted (higher diameter is not available)

refer service case - Service Case 1361907: RCDC software will be collapsed if the model contain an earthquake load combination.if higher diameter is not available and ductile detailing is not satisfied with the available diameter (with minimum spa...
3 months ago in STAAD Concrete 0 Needs review

Older version (11.00) file not opened in 23.00.02.43 version.

please refer to service case: Service Case 1365610 : [CS0156779] RCDC model in Previous version not working in latest version
3 months ago in STAAD Concrete 0 Needs review