RCDC FOOTING DETAIL STARTER BAR

I would like a new feature to be implemented in RCDC, when generating footing drawings , starter bar for the columns should be included in every footing detail as shown in the attached picture
about 2 years ago in STAAD Concrete 2 Needs review

Waffle slab in RCDC / Staad Pro

Include the option to model, design and analyse waffle slab in RCDC/Staad Pro
over 4 years ago in STAAD Concrete 1 Needs review

Add support for Brazilian Codes

Please, add Brazilian codes: Some of the most important codes: ABNT-NBR 6118 (concrete design) ABNT-NBR 6122 (foundations design) ABNT-NBR 8800 (hot-rolled steel design) ABNT-NBR 14762 (cold-formed steel design) ABNT-NBR 7190 (wood design) ABNT-NB...
over 1 year ago in STAAD Concrete 4 Needs review

Testing ideas portal 2

This is a test without logging in
about 3 years ago in STAAD Concrete 0 Needs review

RCDC DESIGN OF A BEAM OF ANY SHAPE CREATED IN USERTABLE

Hello i would like to suggest that RCDC to upgrade and enable it to design any type of beam shape which is created in USERTABLE of STAAD.Pro. i tried early to create a T beam in USERTABLE but after analysis this T beam was not recognized by RCDC
over 1 year ago in STAAD Concrete 1 Needs review

Default material choosing (footing, column, beam, slab) one time in RCDC

Dear bentley software please make one time to choose default materials (concrete reinforcement) for design footing, column ,beam, slab in RCDC, because it waste too time when you select materials and you back to staad change something then you cho...
almost 2 years ago in STAAD Concrete 1 Needs review

Third Design Code IS 456 + IS 13920-1993 + IS 13920-2016 in RCDC | STAAD

In RCDC we are using 2 types of Design Codes Combinations like this. IS 456 + IS 13920-1993 IS 456 + IS 13920-2016 Can't we have Third Design Code IS 456 + IS 13920-1993 + IS 13920-2016 in RCDC (SACD) or STAAD Pro like this? Because In IS 456 w...
over 3 years ago in STAAD Concrete 1 Needs review

DEFLECTION CHECK OF RCC PLATES (RAMP)

Iam designing a reinforced concrete ramp as a plate,the difficult iam facing is there is no BS 8110 in analytical design,and with the available BS 8007 i cant check deflection of the plate.
over 3 years ago in STAAD Concrete 1 Needs review

RCDC ERROR WHILE DESIGNING BEAM (STAAD PRO CONNECT EDITION UPDATE 5)

During design of beam in rcdc,if i put a check of crack width the software will not design and it gives a message written "Cannot find column [StAstTop] but if i dont check for crack width the software works perfectly.Need a help on this problem b...
over 3 years ago in STAAD Concrete 1 Needs review

PARAMETRIC WALL FOUNDATION DESIGN

May you please improve the design of foundation of parametric wall in RCDC,lets say if i want my footing size to be 1500mm by 300mm depth,but the left side i want it to be 400mm from centre of wall and right side to be 1100mm from centre of wall,c...
over 3 years ago in STAAD Concrete 1 Needs review