Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

STAAD.Pro

Showing 445

TO ADD DOUBLE ANGLE FRONT TO FRONT SECTION IN DATABASE

WHILE CREATING A LATTICE FRAME WE NEED TO OPT FOR TWO ANGLES APART FRONT TO FRONT, BUT AS OFF NOW STAAD ONLY PROVIDES DOUBLE ANGLE WITH BACK TO BACK CONFIGURATION AND NOT FRONT TO FRONT, THUS IT IS REQUESTED TO ADD UP DOUBLE ANGLE SECTION WITH FRO...
6 months ago in STAAD.Pro 0 Needs review

Cold formed Member design to EN 1993-1-3

Many STAAD users in Singapore and Malaysia have requested to implement the cold formed member design to EN 1993-1-3. We have lost some prospects to competitors because of the absence of this code in STAAD.Pro. This may be a feature that is request...
almost 3 years ago in STAAD.Pro 3 Future consideration

Separate Equal and unequal angle for in angle section

In most projects, equal angle sections are commonly used. However, the current section database includes a combined list of both equal and unequal angle sections under the same category. To improve workflow efficiency, we request that these be sep...
2 months ago in STAAD.Pro 4 Already exists

[OpenStaad] Add a Design.DeleteDesignCommand function in open staad.

Currently, using the Design.AssignDesignCommand function to add a design command like "CODE CHECK" is ideal only for one execution using VBA. If you execute the code multiple times, the "CODE CHECK' command is added to the command equal to the num...
2 months ago in STAAD.Pro 1 Future consideration

Why isn't there a Eurocode Wind Definitions?

STAAD Pro is used throughout Europe and provides in-depth code checks for most structural analysis. Wouldn't it be a good idea to include the wind parameters from EC3 1-4 in the Wind Definitions rather than only include american, indian, chinese a...
2 months ago in STAAD.Pro 1 Future consideration

Auto load combination for IS 802 part 4

It will be better is auto load combination for following IS codes, IS 802 Part 1/Sec1 2015 - Clause 13 - For Transmission tower Design IS 802 Part 4 2023 - Clause 13 - For latticed switchyard structure Design As of now only design code of IS 802 i...
7 months ago in STAAD.Pro 0 Needs review

SOLIDITY RATIO IN STEEL STRUCTURE

Automation of solidity ratio of steel structure for calculating wing load shall be done. It is very time-consuming process for every structure design.
almost 2 years ago in STAAD.Pro 7 Already exists

Add built-in Protect feature for the model

Sometimes we have to share our models to clients/vendors, and we wish to set a layer of protection on the staad file, such as a password that the user have to enter everytime they try to launch the file. I think it helps to protect corporate and p...
2 months ago in STAAD.Pro 3 Future consideration

Analysis & Design option for Self supporting roofing sheet recommended by RDSO , GOI .........Proflex company MNC is majorly manufacturing those roofing sheets........

Analysis & Design option for Self supporting roofing sheet recommended by RDSO , GOI .........Proflex company MNC is majorly manufacturing those roofing sheets........ The irregular shape of sheet is difficult to model & analyse in staad p...
3 months ago in STAAD.Pro 0 Needs review

Help and Users Manual of Japanese Language in Staad Pro

Let me request to provide the help and Users Manual of Japanese language in Staad pro. Currently It is not existing. So Japanese user cannot use Staad pro as the Calculation Note for Architectural application to Japanese government. If there is it...
3 months ago in STAAD.Pro 1 Planned