Beam Orientation arrows - scale/size

In STAAD.Pro Advanced 2024, please add tool to adjust the scale (size) of the "Beam Orientation" arrows. it is impossible to distinguish from one member to another with the arrows so large.... this was an isolated view of a portion of a much large...
11 months ago in STAAD.Pro 0 Needs review

Add flexible / Semi rigid Diaphragm

Currently only rigid diaphragm option exists in Staad, we need to account for flexible diaphragms.
7 months ago in STAAD.Pro 1 Needs review

Story Shear for Wind and Seismic Loads:

At present, only storey drift & displacements are reported. There is a need to include storey shear values for both the X and Z directions to support comprehensive analysis.- There is an enhancement request already in place for this. For Euroc...
7 months ago in STAAD.Pro 2 Needs review

Indicate of number of LOAD LIST ENVELOPE

As shown in the attached screenshot, the STAAD program does not display the load list envelope numbers, which causes inconvenience for users. Please improve this feature.
9 months ago in STAAD.Pro 3 Future consideration

Add code checks for AISC 370

There is a new code for Stainless Steel that has been published by AISC. It would be nice to incorporate the code checks for AISC 370 for materials that have been selected as stainless steel.
over 3 years ago in STAAD.Pro 10 Future consideration

BUG REPORT REPRESNTAION

Previously, STAAD provided detailed bug reports through the following link: https://bentleysystems.service-now.com/community?id=kb_article_view&sys_kb_id=453e131c47b7ea507798d4fe536d43e8.However, currently, STAAD only shows a one-line descript...
3 months ago in STAAD.Pro 1 Needs review

Inclusion of SS EN 1998-1 Seismic Action & Accidental Torsion

Application of seismic action (including accidental torsion) for structure in Singapore using EN 1998-1 is cumbersome. Request to include this code in future development.
about 1 year ago in STAAD.Pro 2 Needs review

Add possibility to include B1 factor in Code checking Parameters with AISC 360 First Order Method

As per actual possibility provided by AISC 360, it is possible to perform design with Direct Analysis Method but also Effective Length Method and First Order method. In some case it is useful to do analysis with First order method (Dynamic Seismic...
10 months ago in STAAD.Pro 0 Needs review

Staad.Pro 2025 Serviceability Check include section from Mexican Tables

Serviceability check doesn't work when using sections from Mexican Tables or prismatic sections producing the error: "To use this tool the model should have section profiles and materials assigned to all members." When I change all my sections to ...
5 months ago in STAAD.Pro 1 Already exists

Cold formed Member design to EN 1993-1-3

Many STAAD users in Singapore and Malaysia have requested to implement the cold formed member design to EN 1993-1-3. We have lost some prospects to competitors because of the absence of this code in STAAD.Pro. This may be a feature that is request...
over 3 years ago in STAAD.Pro 3 Future consideration