In Staad Pro 23.00.02.361, the size of the local coordinate system arrow cannot be enlarged or reduced simultaneously with the model. At present, the size of the local coordinate system arrow is too large. When there are many rod elements in the model, the local coordinate system almost covers the entire model, affecting other operations. Please provide improvement.

No description provided
  • Admin
    Carlos Aguera
    Reply
    |
    Feb 6, 2024

    Thank you for posting this idea. The current system for scaling the orientation symbol is based on all the members in the current view. The scale being determined by the longest member. If you just select the shorter members and create a new view, then the orientation symbols should be suitable for your needs