Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 653 of 653

Beam -Detail-Text Too Small in Beam Detail View - Enhancement

In RCDC the beam detail text are too small in beam detail view. This needs to be enhanced for better readability. Refer Feature (PBI) #1720589
about 19 hours ago in STAAD Concrete 0 Needs review

Include reactions from control nodes in the Statics Checks summary

This idea is submitted on behalf of Michael Mills from Payne-Huber Engineering STAAD.Pro won't currently include the reactions from Control Nodes in the Statics Check. Although this is documented (TR.28.1 Control/Dependent Specification), it can l...
2 days ago in STAAD.Pro 1 Future consideration

Shape Editor. Allow some properties to be modified before exporting to UPT

This idea is submitted on behalf of Jose Castañeda from Integra Construcciones Metalicas The Shape Editor will automatically fill AY and AZ zero values that can later trigger errors in STAAD.Pro. If these are up to the user to determine, it would ...
3 days ago in STAAD.Pro 0 Needs review

Make the detailed AISI design output available in the Reports Workflow

This idea is submitted on behalf of Cameron Empey from Betchtel. There's no way to include the TRACK 2 AISI output in the report. Please make that an available item to add. PBI Ref:1785991
3 days ago in STAAD.Pro 1 Future consideration

Reports Workflow. Improve table formatting

This Idea is submitted on behalf of Adane Teferi, from HDR. The table formatting for some tables is a bit too crowded to be readable. Headers and cells' contents alike are sometimes spilled over multiple rows without a definite pattern. Also, note...
3 days ago in STAAD.Pro 1 Needs review

Request for code update For vertical & horizontal vessel foundation

For vertical & horizontal vessel foundation include the below codes. ASCE 7-22 ACI 318-22 Refer Feature (PBI) #1990147
4 days ago in STAAD Concrete 0 Needs review

Automatic Load Scaling

The floor loads in dead and live load cases are shown in some default scales. We can change the scale manually but it does not stay. Whenever the different load items from different load cases are selected the scale get reset. The user defined sca...
22 days ago in STAAD.Pro 0 Needs review

Adding measurement tool

The node‑to‑node distance tool in STAAD.Pro is quite basic and, in its current form, not particularly useful when distances need to be measured independently along the X, Y, and Z axes. Bentley already provides this functionality in some of its ot...
2 months ago in STAAD.Pro 1 Needs review

Provide STAAD Foundation Advanced a method to manage the link to a STAAD.Pro model

When a STAAD Foundation model is created from a STAAD.Pro model, that is added to the STAAD.Pro folder. This process creates pointers in both data sets that link the two models together and allow for notification when changes takes place. However,...
about 1 month ago in STAAD.Pro 7 Future consideration

Inclusion of the newly released Indian Seismic Code IS 1893 (Part 1&5): 2025 in STAAD.Pro.

Since STAAD.Pro currently supports earlier IS 1893 versions, having the 2025 version integrated will be essential to ensure code-compliant analysis and safe design in India. The 2025 revision introduces major updates: A revised earthquake zone m...
4 months ago in STAAD.Pro 3 Planned