Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 373 of 373

Design of foundation with Shear links in staad foundation advance SFS

Design of foundation with shear link is not available in staad foundation advance (SFA). It is very necessary to implement the design of various foundation/s along with shear link design options also. Especially as per Indian standard codes.
4 days ago in STAAD Concrete 0 Needs review

Modify design parameter "PROFILE"

Design Parameter "PROFILE" seems to check only first 3 characters. If I understand correctly, STAAD already selects the lightest section only for the same kind of section as the current one, and the limit on the height can be set by variables DMAX...
5 days ago in STAAD.Pro 2 Planned

Calculation of Stability index Q as per annex E of IS456

To determine whether a column is a no sway or a sway column, stability index Q may be computed as given in annex-e of IS456. It's a very time consuming and cumbersome calculation while we are freezing the column sizes. if Q is directly calculated ...
6 days ago in STAAD.Pro 3 Future consideration

Tables with inbuild worksheet like sorting facilities

When sorting information in a worksheet, you can rearrange the data to find values quickly. You can sort a range or table of data on one or more columns of data. you can sort load cases in display tables for both input and output data directly in ...
6 days ago in STAAD.Pro 1 Already exists

Automatic Plate Meshing

Set parameters and have the program create a plate mesh automatically for finite element analysis.
14 days ago in STAAD.Pro 5 Already exists

implement front to front angle configuration in STAAD

In India many Columns are made with 4 leg of angle with lacing of rod or angle(built-up) STAAD have option of design back to back but it is not have front to front angle configuration
20 days ago in STAAD.Pro 1 Will not implement

ADD the slenderness ratio to the normalized ratio

If the slenderness ratio meets the requirements, but its normalized ratio is not shown in the utilization table, can the slenderness ratio be added to the utilization table, which will help the designer to understand the condition of the member.
21 days ago in STAAD.Pro 1 Needs review

Introduce "Dynamic pictures" for quick reports update

Hello, Could you introduce "Dynamic Pictures" in STAAD? Engineers spend a good amount of time in generating clearly annotated and detailed reports within all project's lifecycle. In a competitive environment, hitting timelines is paramount. A dyna...
25 days ago in STAAD.Pro 1 Future consideration

Provide detailed calculations and formulas

Can you provide calculations which are similar to the connection design, i.e. include detailed calculations as well as formulas?
28 days ago in STAAD.Pro 1 Will not implement

ANGLE STAR AISC LRFD CODE CHECK

No description provided
28 days ago in STAAD.Pro 3 Needs review