ADD the slenderness ratio to the normalized ratio

If the slenderness ratio meets the requirements, but its normalized ratio is not shown in the utilization table, can the slenderness ratio be added to the utilization table, which will help the designer to understand the condition of the member.
about 1 year ago in STAAD.Pro 1 Needs review

mass Load generator in Physical Modeller

It would be useful if Mass Model generator is included in physical Modeller.
about 1 year ago in STAAD.Pro 1 Needs review

Incorporate ACI-350 into RCDC

HDR designs many concrete water tanks (round and square). We use STAAD to generate a FEM mesh and then use the stresses to design the concrete elements with load factors unique to ACI-350.
over 1 year ago in STAAD Concrete 4 Needs review

Hi, I am wondering when STAAD RCDC would be equipped with CSA A23.3?

Hi, I am wondering when STAAD RCDC would be equipped with CSA A23.3? Thanks
over 1 year ago in STAAD Concrete 0 Needs review

It is hoped that the number of decimal places for the section thickness display can be increased to three, or the display unit of the section can be controlled.

No description provided
7 months ago in STAAD.Pro 1 Needs review

automated loading for intz tank

automated tool for hydrostatic loading should be included
about 1 year ago in STAAD.Pro 1 Needs review

Calculator from the Input Editor / Command File

I wouldn't lie by saying that I'm a vivid user of the calculator from the withing the Input Editor/Command file. But at times when the Window's calculator crashes, Staad's calculator comes to the rescue. hoping to add a few suggestions: 1. rather ...
7 months ago in STAAD.Pro 1 Needs review

Tapered bracket cantilever design

In design of buildings sometimes we need to takeup tapered bracket or counterbalance supported tapered cantilever cross section At the moment we can not design tapering cross section in staad pro connection edition
over 2 years ago in STAAD.Pro 1 Needs review

Strap foundation design as per Indian code

Staad foundation advance supports design of structural strap of strap foundation as per ACI code , i.e not designed the structural strap of strap foundation as per Indian code. Hence add the features of design strap foundation along with structura...
about 1 year ago in STAAD Concrete 0 Needs review

Request Omitted Data from IBC/ASCE7 Seismic Load Generator

There is no method, report, or output command available to display the "k" coefficient used by the program for vertical distribution of seismic base shear per ASCE 7-16, Eq 12.8-2. Since this value can vary with the period it needs to be reported ...