Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

My ideas

Showing 537 of 537

Reuse the water tank module to form a retaining wall module in SPPM

Are there any plans to use the Water Tank module in Structure Wizard in the Physical Modeler to create a retaining wall module? It seems like this could be developed easily from the water tank module.
over 2 years ago in STAAD.Pro 1 Needs review

Exporting Physical members from Staad Pro to RCDC

Hi I have an exceedingly large model which takes hours to run on RCDC. Also, when the model is exported from STAAD to RCDC, all the beam support points are not detected properly by RCDC and I have to spend days just correcting the Beam Continuum. ...
10 months ago in STAAD.Pro 1 Needs review

for RCDC software, Please add the result and calculate about Failed Member to help designer update the model

when I use RCDC, the column failed to crack-width,but I want to know the result of failed column crack-width value and calcute to deside how to update the model, update Longitudinal reinforcement or stirrup
10 months ago in STAAD Concrete 0 Needs review

automatic coupling plate element boundary

Need a function similar to Midas automatic coupling plate element boundary
10 months ago in STAAD.Pro 1 Already exists

Full integration with AutoPIPE and STAAD

Pipelink is quite rudimentary. It does not provide the ability to assign guide supports to different nodes. For example, horizontal loads need to be applied to Vertical Members, while vertical loads need to be applied to Horizontal Members. The sa...
10 months ago in STAAD.Pro 3 Needs review

Please provide report data in txt format for export in versions after 2023, as we need to maintain consistency with previous versions

Please provide report data in txt format for export in versions after 2023, as we need to maintain consistency with previous versions
10 months ago in STAAD.Pro 1 Needs review

Lift Permissible Effective length Factor is 5 in RCDC

Currently in Column Design, RCDC has a limit on the maximum value of the effective length factor and users cannot modify this limit value 5. I want RCDC to lift the restriction on this factor. In my case as per attached staad, Column effective len...
10 months ago in STAAD Concrete 1 Needs review

Additional Selection Tools

It would be much helpful if additional tools to select entities like Nodes, Beams etc., in the polar coordinate system i.e., specifying the start and end radius (or diameter) and start and end angles. This helps a lot if we need to select the enti...
10 months ago in STAAD.Pro 1 Will not implement

OpenSTAAD function to remove the unused isotropic materials

Staad by default adds some materials to the model (please refer to the snapshot attached). Majority of these will not be used during automation (as the materials will be created separately based on the need) and hence the materials section remains...
over 1 year ago in STAAD.Pro 1 Future consideration

Show section shape from Section wizard

Hello dev team, As of now, STAAD cannot show the section shape from section wizard . This issue may make the engineer confuse about local axis even we can referent to the (v,u) axis. its will be good if STAAD can show the section shape that custom...
over 1 year ago in STAAD.Pro 1 Will not implement