STAAD.Pro

Showing 181

Postprocessing member design/revision without re-run analysis

Currently after run analysis we can see the status of design in postprocessing. If fail design appear, now we have to edit and rerun all model and check if edition is good or not. When only 5~10% of members fails, and in large models, this is very...
over 2 years ago in STAAD.Pro 1 Future consideration

implementation of design of double ISMB Box section profile while designing in code IS-800-2007-LSD.

When we are assigning ISMB 400*450 Box Section (Double Profile) while designing in Code IS-800-2007-LSD , Members are not able to design & Error coming. Kindly resolve the issue.
over 2 years ago in STAAD.Pro 1 Future consideration

Add Functionality to run a Direct Analysis following AISC 360 C.2a

Unless I am mistaken in order to run a direct analysis, you specify notional loads. However, per the specification it is allowable to use direct modeling of imperfections per C.2a. There is a way to specify camber and drift for members, but from w...
over 2 years ago in STAAD.Pro 1 Future consideration

Size of joint release and beam orientations

In Staad, is there any way to reduce the size of pin symbol and beam orientation symbol? Like support symbols. Thanks
over 1 year ago in STAAD.Pro 1 Future consideration

Design classification in Load Cases Definition

Include a Design category as part of the load case/combination definition so that when a design includes the load case/combination, it 'knows' how to consider the analysis results in the design without having to create a load envelope of a given t...
over 1 year ago in STAAD.Pro 0 Future consideration

Sorting function of member properties

A really useful feature for steel structures would be a function to sort all the section properties alphabetically/numerically. In large structures it becomes very hard to follow what section is what once you hit around 100 different section prope...
over 1 year ago in STAAD.Pro 1 Future consideration

Pipelink Transfer Loading Improvement

The Transfer Loading dialog in the Piping workflow is limited in functionality. It could be improved by adding a checkbox to change the Action and Class columns for all loads. If I want to change all the loads to primary loads, it is very tedious ...
over 1 year ago in STAAD.Pro 1 Future consideration

Tapered Sections naming in STAAD.Pro

I think it is a good idea to allow users to name their Tapered sections as with the prismatic sections or sections created by user table. Because many times user creates many tapered sections in his model, andt when it comes to modifying one of th...
over 4 years ago in STAAD.Pro 2 Future consideration

Design wide flange with cover plates to EN1993-1

Currently design of I plate with cover plates are not yet implemented in Euro code for STAAD. This idea is to add support for this capability.
over 1 year ago in STAAD.Pro 1 Future consideration

section detail backup

every time when we update software, it should be notified to take necessary backup of added section for cold form, it is really painful doing same work in 1-2 month while software is being updated. it will save designerr time
over 1 year ago in STAAD.Pro 1 Future consideration