Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

STAAD.Pro

Showing 362 of 426

Scale factor for displacement quantities in response spectrum analysis as per IS 1893:2016 amendment no-2 (additional clause 7.7.3.2) regarding

It is understood that while performing response spectrum analysis, the scale factor (V_b/V_B ) Where,V_b=Equivalent static base shear,〖 V〗_B Response spectrum base shear), is automatically accounted for calculation of design base shear. But,this s...
5 months ago in STAAD.Pro 0 Needs review

Add load to the node/beam/element group using OpenSTAAD

Hi, I have an OpenSTAAD program that generates groups and that applies loads to the elements/beams/nodes in those groups. However I'd like to apply the load to the group directly using openSTAAD as you can in the STAAD Command File? What I want to...
11 months ago in STAAD.Pro 1 Future consideration

Provide wind generation on Fireproof Members

STAAD does not consider the additional width of the fireproofed members; producing underestimated wind generated loads for open structures like piperacks. Please include this feature as this would make several of my colleagues happy.
about 5 years ago in STAAD.Pro 5 Future consideration

Ciudad de Mexico NTC code 2023

To update/include the specifications for mexican regulation for Ciudad de Mexico to the latest version 2023 which include loads specifications, seismic, wind, or at least the steel and concrete.
6 months ago in STAAD.Pro 1 Future consideration

Function to Apply Hydrostatic Pressure using OpenSTAAD

It will be helpful if a function for applying the hydrostatic forces on plate elements either by selecting a group of plates or a selecting a single plate e.g., the PlateID and the pressure at four corners of the plate. Many a times applying the p...
over 1 year ago in STAAD.Pro 2 Already exists

Add NZS 1170.5 code to Seismic Codes in STAAD

STAAD does not have NZS 1170.5 in its Seismic Codes. Users in ANZ uses custom spectrum and factored it up to match the base shear. Adding this code will help the users in ANZ work directly with the NZ code and thus speed up their productivity. Use...
over 2 years ago in STAAD.Pro 1 Future consideration

Multiple mass models/ seismic analyses for design

Many codes, particularly IS 1893 part-2 and IS 3370 part-2, the RCC elevated/underground water retaining structure should be analyse and design in "TANK ENPTY" and "TANK FULL" both of the conditions, but staad pro seismic definition whether it is ...
over 2 years ago in STAAD.Pro 2 Future consideration

Modeling & designing of different types of staircase

Staad pro should have an option to model each and every type of staircase like single flight (straight)stairs,dog ledged strair, spiral stair, U shape stairs,L shape stairs,winder, double winder, 2 quarter winder, 2 quarter landing,curved staircas...
12 months ago in STAAD.Pro 1 Will not implement

Modeling of trapezoidal pattern plates (for raft foundation) in staad pro

Till now, staad pro has an option to assign plates of various thickness, but it should also have an option to model such plates in TRAPEZOIDAL PATTERN as shown in below images,which is frequently used to model raft foundation, also placement and b...
12 months ago in STAAD.Pro 1 Already exists

Steel structure optimization for tapered sections and built-up section

Optimization of steel structure in staad pro as per (Indian code like IS-800 _2007, IS-801 etc. has many limitations till now. It has to be resolved earlier, Some of limitations are ~ optimization for tapered sections not supported by staad ~ opti...
12 months ago in STAAD.Pro 1 Needs review