Beam Continuity - Issue found while modifying Beam Continuity in RCDC

Refer attached video. The issue occurs when we perform MERGE functionality after SPLIT functionality. A new issue is added on 7th September 2023.Issue related to Beam type after modifying beam continuity:Service Case 1276842: [CS0074014] Beam Desi...
3 months ago in STAAD Concrete 0 Needs review

Pilecap -Reinforcement drawing enhancements.

refer Service case Service Case 1268761: [CS0072116] Pile cap DrawingThe client has shared a sample drawing for reference.
3 months ago in STAAD Concrete 0 Needs review

Open STAAD function for changing a existing tapper property

Please add one open STAAD function in which we can edit existing tapper property it will same much time
9 months ago in STAAD.Pro 1 Needs review

Capacity Design as per NZS3404

Currently STAAD is performing only geometrical check of the members in accordance with Chapter 12 of NZS 3404. However, no design is performed based on the capacity design principles provided in this Chapter. As industries in New Zealand is increa...
3 months ago in STAAD.Pro 0 Needs review

RCDC DESIGN OF COLUMN INCLINED AT AN ANGLE.

I would like to suggest the addition of column designs that are inclined at an angle. You may find a project having many columns inclined at a certain angle; it will consume a lot of time to design them manually, as RCDC is not capable of designin...
6 months ago in STAAD Concrete 1 Needs review

RCDC DESIGN OF BEAM INCLINED AT AN ANGLE.

Hello i would suggest STAAD and RCDC to implement design of beams which are inclined at angle to meet project requirements.
6 months ago in STAAD Concrete 0 Needs review

Steel AutoDrafter Implementation Required

Dear Sir / Madam, Steel Auto Drafter is not giving beam presentation as per Releases provide in Analytical Modelling. Please check attached screenshot for your ready reference. Steel AutoDrafter drawings should be as per Release and Analytical mod...
almost 2 years ago in STAAD.Pro 7 Future consideration

RCDC - Beam Design - Long term deflection check should be available

For the structures like Metro railway station and Industrial buildings, Clients are demanding to perform the long-term deflection check of the beam. RCDC should allow to perform the long-term deflection check for the beams selected by the user. Ge...
over 2 years ago in STAAD Concrete 1 Needs review

Can we transfer maximum thermal load ( thermal 1, thermal 2, thermal 3) from autoPIPE pipelink to STAAD.Pro.

No description provided
3 months ago in STAAD.Pro 0 Needs review

Wind Loading on Tapered Sections

Dear Colleagues, // STAAD.Pro CONNECT Edition - Version 22.12.00.142 // there was a situation where we had to find out the lateral forces due to wind on a light pole (tapered profile) and provide suitable support for the same. Wind was applied usi...
over 2 years ago in STAAD.Pro 1 Future consideration