Canadian Seismic Load per 2015 NBC code parameters

Would like to get implemented NBC 2015 Code parameter.
over 1 year ago in STAAD.Pro 0 Future consideration

Provide wind generation on Fireproof Members

STAAD does not consider the additional width of the fireproofed members; producing underestimated wind generated loads for open structures like piperacks. Please include this feature as this would make several of my colleagues happy.
over 5 years ago in STAAD.Pro 5 Future consideration

I sections with side plates

It is suggested to add I sections with side plates table under specifications user table manager tabs. Offshore brownfiled modificaitons work would involve adding side plates to existing I sections to increase its capacity.
over 1 year ago in STAAD.Pro 1 Needs review

WIND CORNER PRESSURE AND ROOF IN WIND LOAD GENERATOR

Hello i would like to drop my suggestion for consideration, as we know up to now Wind Load generator, can only generate wind on panels. But during design we may have to apply corner wind pressure especially in connection design and also to apply w...
over 2 years ago in STAAD.Pro 2 Needs review

Staad Pro does not include Seismic load NBCC 2015

Dear All, I highly recommend to include calculation of seismic load using NBCC 2015. I see it as a big gap in Staad Pro not to include Seismic loading using NBCC 2015 Thanks a lot
over 4 years ago in STAAD.Pro 1 Future consideration

Add an option for optimize to specify equal leg angles.

It would be nice to tell the optimizer to optimize to angles where the angle legs are equal. By default I prefer to specify equal legs, as it eliminates confuse and chances of error when the legs are the same size. So even if the optimizer suggest...
6 months ago in STAAD.Pro 0 Needs review

Is there any possibility to update IS 802 latest code in stadd pro connect in near future?

Is there any possibility to update IS 802 latest code in stadd pro connect in near future? Till now IS 802 1995 is provided instead of IS 802 2016
6 months ago in STAAD.Pro 0 Needs review

Stress Ratio Results for Multiple Load Cases

Show code check results for more than just the worst case. Should be able to see what the next worst, and next worse after that and so on. It's been over 10 years since I used it but I believe SACS does this. If so, could take a look at it.
about 2 years ago in STAAD.Pro 3 Future consideration

Add the ability to add wind loads to plate elements

It would be nice to be able to apply wind loads on plate elements. Especially given that there is a wind load definition specifically for tanks, but no way to model that tank other than plate elements. The alternatives are a cumbersome to implemen...
over 3 years ago in STAAD.Pro 2 Future consideration

Rigid diaphragm on inclined floor/pitched floor/roof

Staad pro doesn't support for modelling of rigid diaphragm for inclined floor/inclined slab/inclined roof, so that response spectrum analysis can not be achieved in this case, so it is necessary to implement feature of modelling rigid diaphragm/se...
over 1 year ago in STAAD.Pro 1 Already exists