Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 545

Wind Loads on Steel Structures

I think the wind load application should be rewritten to make it simpler and more user friendly. STAAD is at least three times as long as SAP2000 when inputting wind loads.
about 2 years ago in STAAD.Pro 12 Needs review

RCDC enable read incline floor beam

No description provided
over 3 years ago in STAAD Concrete 0 Needs review

Cold form section outside the standard library not designed in STAADpro as per IS801

STAADpro is not able to design cold form section outside the standard library or any user defined cold form section as per IS801. This is severe limitation as many users are using sections of their choice which are not in the library. This is espe...
4 months ago in STAAD.Pro 1 Future consideration

Design of double channel section in STAAD needs improvement

At present design of double channel in STAAD as per IS800 LSD is having certain work flow. It assumes higher MI as a major axis even if it can be about minor axis Y which is not correct. STAAD should consider section orientation as provided by use...
4 months ago in STAAD.Pro 1 Already exists

Design of double I section as column is required.

In most of the industrial sheds, double I section spaced apart is used as crane column and single I section is used to support the roof above. In present STAADpro ver 24 facility to design double I section as per IS800 LSD is not available . This ...
4 months ago in STAAD.Pro 1 Needs review

Add grid lines

Grid lines are already included when using Auto Drafter. That idea could be very useful in GUI.
about 2 years ago in STAAD.Pro 3 Future consideration

Moving Load Moving in Global Vertical Direction

The ability to apply horizontal moving loads that move in the vertical direction (up a column) (e.g. elevator loads on a column).
over 2 years ago in STAAD.Pro 3 Future consideration

AUTOMATIC BUCKLING EUROCODE COEFFICIENTS C1,C2,C3 and K.

For the eurocode to calculate automatically the factors C1,C2,C3 to calculate correctely the Mcr value for elements. Which depends on the bending moment diagram, loading type and support conditions.
9 months ago in STAAD.Pro 1 Will not implement

Report Header Needs Line for "Subject" - STAAD.Pro 2024

STAAD.Pro 2024 output data is published via the Reports module. That data for one structural model can be used to present different subjects. Unfortunately, the 2024 report pages do not include a line in the header to show the "SUBJECT" of that pr...
9 months ago in STAAD.Pro 3 Future consideration

Update ASCE7 to the latest version 7-22

Currently, ASCE7-22 is not available in STAAD. Pro. Wind and Seismic load generation with this code is required for our project execution.
over 2 years ago in STAAD.Pro 1 Future consideration