Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 553

Provision of status bar to extract plate stress and visual representation at any desired direction

I am trying to model in physical modeler of staad and it gives random orientation of plates. Now if I have to read and visualize the stress in particular direction ( not only for one line), i am not able to do that. if possible, please provide a b...
5 months ago in STAAD.Pro 8 Future consideration

Update ASCE7 to the latest version 7-22

Currently, ASCE7-22 is not available in STAAD. Pro. Wind and Seismic load generation with this code is required for our project execution.
over 2 years ago in STAAD.Pro 1 Future consideration

AUTOMATIC BUCKLING EUROCODE COEFFICIENTS C1,C2,C3 and K.

For the eurocode to calculate automatically the factors C1,C2,C3 to calculate correctely the Mcr value for elements. Which depends on the bending moment diagram, loading type and support conditions.
10 months ago in STAAD.Pro 1 Will not implement

Report Header Needs Line for "Subject" - STAAD.Pro 2024

STAAD.Pro 2024 output data is published via the Reports module. That data for one structural model can be used to present different subjects. Unfortunately, the 2024 report pages do not include a line in the header to show the "SUBJECT" of that pr...
10 months ago in STAAD.Pro 3 Future consideration

Staad Pro Structure Wizard (StWizard) - Pan & Zoom

For the Structure Wizard in the Analytical workflow:- Mouse Zoom behavior could be aligned with that of the STAAD interface (in STAAD - scroll up is zoom-in and scroll down is zoom-out) Pan by mouse could be advantageous, so is exiting the PAN mod...
about 2 years ago in STAAD.Pro 2 Will not implement

Time History in multiple load case for blast loads

For Blast loads in some cases we have to apply blast load in all the direction i.e x and z in different load cases. presently the time history load is possible only in one load case. Time history should be allowed to be added in mutiple load cases
over 1 year ago in STAAD.Pro 3 Future consideration

Please add the following South African Concrete Standards (SANS) to the RCDC (STAAD Advance Concrete Design) Program

Main SA Concrete Design Code SABS 10100-1:2000 Edition 2.2. The Structural use of Concrete Part 1: Design Supplementary SA Concrete Design Codes SABS 10100-2:2014 Edition 3 The Structural use of Concrete Part 2: Materials and Execution of Work SAN...
about 2 years ago in STAAD Concrete 1 Needs review

Cold form section outside the standard library not designed in STAADpro as per IS801

STAADpro is not able to design cold form section outside the standard library or any user defined cold form section as per IS801. This is severe limitation as many users are using sections of their choice which are not in the library. This is espe...
5 months ago in STAAD.Pro 1 Future consideration

Design of double channel section in STAAD needs improvement

At present design of double channel in STAAD as per IS800 LSD is having certain work flow. It assumes higher MI as a major axis even if it can be about minor axis Y which is not correct. STAAD should consider section orientation as provided by use...
5 months ago in STAAD.Pro 1 Already exists

Design of double I section as column is required.

In most of the industrial sheds, double I section spaced apart is used as crane column and single I section is used to support the roof above. In present STAADpro ver 24 facility to design double I section as per IS800 LSD is not available . This ...
5 months ago in STAAD.Pro 1 Needs review