display of design results for different design parameters

It is understood that only for AISC 360 design checks, it is feasible to view the design results for different design parameters & maximum case, while the same is not allowed for other design codes without going in to output file. Appreciate t...
over 2 years ago in STAAD.Pro 5 Future consideration

Customization of Auto steel drafter For tapered sections

ear Eng: I was Suggest if we can do the following - generate the drawings with the legend "Rxx" ? - Replace the current table shown in the snapshot with the section properties table attached the snap shot that can show the required
over 2 years ago in STAAD.Pro 2 Future consideration

FLAT SLAB, RIBBED SLAB AND WAFFLE SLAB

May you please include the design of waffle slab, ribbed slab and flat slab in rcdc
over 4 years ago in STAAD.Pro 1 Future consideration

Add angles measurement tool

It would be helpful to add a measurement of angles function to the program especially when dealing with complicated angles and geometry it will help speed up the modeling process and aid in efficiency.
over 2 years ago in STAAD.Pro 2 Needs review

make RCDC read steel column for design footing

hi When you importing portal frame building in to RCDC for design concrete footing,display column is missing in RCDC,becuase columns are steel,make RCDC read for design footing thanks in advance
over 3 years ago in STAAD Concrete 1 Planned

Improvement to the Quality of Staad Advance Foundation detail Drawings

I am recommending that the same software engineers that is responsible for producing the detail drawings for RCDC should be responsible for producing the drawings for Staad Advance Foundation Design. The Detailing drawing designs in Staad Advanced...
over 3 years ago in STAAD Concrete 3 Planned

Add "highlight assigned geometry" checkbox to the Loads window

Adding "highlight assigned geometry" checkbox to the Loads window would be a beneficial feature to see what members loads are applied to. It would also be more consistent with the other tabs: Properties, Specifications, etc.
over 2 years ago in STAAD.Pro 1 Future consideration

Make Material Definition properties apply for steel design

Currently, according to Bentley Support, the Material Definition properties are only used in the Connection Design module and are not used for steel design & code checking. The SGR, FYLD, FU parameters must be used instead to define the materi...
over 2 years ago in STAAD.Pro 5 Future consideration

Use Center of the Structure as rotation Center

The Orientation Settings window provides the option "Use the center of the structure as the rotation center". However, when i perform the "Display Whole Structure" function, the rotation center is reset to 0,0,0. This happens when the Orientation ...
about 1 year ago in STAAD.Pro 0 Needs review

Design of foundation with Shear links in staad foundation advance SFS

Design of foundation with shear link is not available in staad foundation advance (SFA). It is very necessary to implement the design of various foundation/s along with shear link design options also. Especially as per Indian standard codes.
over 1 year ago in STAAD Concrete 0 Needs review