Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 531

Physical Modeler - Allow multiple wind load definitions to be combined into one primary load case

Because you must create multiple wind definitions for wind along a single direction (i.e. windward, leeward, sidewall) it would be helpful to have the ability to combine these in a single load case. Combining them in the load combos is cumbersome....
almost 3 years ago in STAAD.Pro 1 Future consideration

Add a command to modify tension Flange net area for AISC 360 F13

There is the command NSF that modifies the net area of the whole member, but there isn't a command to modify the net area of the tension flange only to apply it to section F13 in AISC.
almost 3 years ago in STAAD.Pro 2 Future consideration

Auto reducible live load in Staad for IS 456 part 2

No description provided
almost 3 years ago in STAAD.Pro 3 Future consideration

Reducuble live load in staad CE as per indian code

No description provided
almost 3 years ago in STAAD.Pro 2 Already exists

Lacing and battening design of column

No description provided
almost 3 years ago in STAAD.Pro 2 Will not implement

control tolerance ratio Steel- utilization ratio.

Good morning Srs. I would like to control tolerance ratio Steel- utilization ratio.
over 1 year ago in STAAD.Pro 3 Future consideration

OSLoadUI::CreateLoadEnvelop function name is wrong

Please refer to the snapshot attached. The OSLoadUI::CreateLoadEnvelop function name is wrong. Please update in the next releases. Initially I could not find this function in the intellisense (by typing Create and left me wondering) and hence I am...
over 1 year ago in STAAD.Pro 1 Will not implement

Getting the beam & column reinforcment in table format in the design report

Report generation is significantly improved in the latest version. it will be great, If user able get the beam & column design details like , grade of concrete, member size, reinforcement required, reinforcement provided etc. in an table forma...
over 1 year ago in STAAD.Pro 1 Needs review

GetUDLLoads command has probrem

I am testing Load.GetUDLLoads command. The contents of the returned D1Array will always be 0. For example, 1992 UNI 0.100 7.750 10.250, since 7.750 is not returned in D1Array,I can not check the range which the load is applied . D2Array truely ret...
over 1 year ago in STAAD.Pro 1 Will not implement

Using arbitrary Young's modulus (E) in AIJ2005 code calculations

In the current AIJ2005 code allowable stress calculation of STAAD.Pro, the Young's modulus is fixed at 205000 (N/mm2). On the other hand, in the AIJ2002 code, by using the YNG=1 parameter, the Young's modulus used in the frame analysis can be use...
over 1 year ago in STAAD.Pro 3 Future consideration