Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 545

Add 75Deg had section database

in standard section data base only 90Deg hat is available, we are mostly using 75Deg hat
14 days ago in STAAD.Pro 2 Needs review

Render Profiles from Shape Editor in STAAD.Pro

If i create any member using "Shape Editor" using built up members (Stadd pro version 24.00.02.354), then during "3d rendering" it shows only line diagram. Although this problem is continuing from the earlier version also. Is ther any solutions of...
3 months ago in STAAD.Pro 1 Needs review

Request to keep beta angle 0

Sometimes, a member requires the assignment of a Beta Angle for a particular member, but after some iterations, it might not be needed. In the Beta Angle assignment tab, when someone defines a Beta Angle, it exists—but Beta Angle 0 is removed. In ...
17 days ago in STAAD.Pro 2 Already exists

To add Brazilian Design Code / NBR (Normas Brasileiras)

In light of the increasing opportunities in the construction business in Brazil, we strongly hope that STAAD Pro will support the Brazilian codes "NBR" in STAAD Pro. Specifically, we would like to see the following representative NBR codes include...
10 months ago in STAAD.Pro 4 Needs review

Implementation of IS18168 for steel design in STAAD Pro

No description provided
about 2 months ago in STAAD.Pro 1 Planned

implement the GFRP design of members as per ACI 440-1R-15.

The FRP rebar is future of replacement for mild steel rebar. it is most useful for design of member like beam, column, slab and foundation. in the infrastructure project it is mostly used. This is very useful for the future.
18 days ago in STAAD Concrete 0 Needs review

Update of Canadian Code CSA 23.3 in STAAD Pro

For the design of concrete structures and foundations that will require permit approval in Canada, a recent code is expected. CSA code available in STAAD Pro Connect Edition is still CSA 23.3-94. Currently the latest code is 2019 but the 2014 is a...
almost 3 years ago in STAAD Concrete 5 Planned

STAAD.Pro AISC/CSA Code Checks - Eccentric Axial Specification

There is currently no way, other than directly adding rigid body members with the necessary releases, to simulate an an axial angle or tee member (brace) under eccentric axial load. This causes a high amount of manual calculations to determine the...
5 months ago in STAAD.Pro 4 Needs review

Inclusion of Steel Take off list & Member take off list in User Report

I have noticed that currently there is no option to include Steel take off & Member take off list while generating Report. I request that this option be included in future upgrade.
about 1 month ago in STAAD.Pro 6 Planned

Add flexible / Semi rigid Diaphragm

Currently only rigid diaphragm option exists in Staad, we need to account for flexible diaphragms.
about 2 months ago in STAAD.Pro 0 Needs review