Request to Include the Interaction Diagram in the Calculation Report – STAAD Foundation Advanced v2024

Please include the interaction diagram in the calculation output report for pedestals in STAAD Foundation Advanced 2024, as was done in version V9. Currently, the report shows the coordinates of the load points but does not include the associated ...
about 2 months ago in STAAD Concrete 0 Needs review

Verification of User-Defined Steel Reinforcement

Good morning. It would be helpful if future versions included the option for the user to define the reinforcement layout, allowing STAAD Foundation Advanced to verify it — both for pedestals and foundations
7 days ago in STAAD.Pro 0 Needs review

STAAD.Pro AISC/CSA Code Checks - Eccentric Axial Specification

There is currently no way, other than directly adding rigid body members with the necessary releases, to simulate an an axial angle or tee member (brace) under eccentric axial load. This causes a high amount of manual calculations to determine the...
2 months ago in STAAD.Pro 4 Needs review

CANADA/NRC seismic code 2023

Presently Staad pro is using CANADA/NRC seismic code 2010, but available code is 20213 , kindly update your Staad soft ware accordingly, to perform our Canadian client asap
12 days ago in STAAD.Pro 0 Needs review

AutoDrafter - Show Tee Sections (From Halved Wide Flanges) as the WT callout

Sometimes these drawings are sent to other colleagues that do 3D modeling, and sometimes do not know that W200x27 TEE === WT100x13. It would be an improvement for the Schedule of Sections and MTOs show the correct WT callout, when a STAAD users sp...
2 months ago in STAAD.Pro 1 Future consideration

Untie the Section Name in the Properties window from the Base Unit settings

The proposed enhacement would allow the units that are being used in the model to appear correctly and complete in the Section Name window, and also in the reports because, for example, being tied as they are now only allows units to be presented ...
13 days ago in STAAD.Pro 0 Needs review

To add Brazilian Design Code / NBR (Normas Brasileiras)

In light of the increasing opportunities in the construction business in Brazil, we strongly hope that STAAD Pro will support the Brazilian codes "NBR" in STAAD Pro. Specifically, we would like to see the following representative NBR codes include...
8 months ago in STAAD.Pro 4 Needs review

AutoDrafter - Save as PDF

Please allow option to save drawings from AutoDrafter to PDF.
2 months ago in STAAD.Pro 0 Needs review

AutoDrafter - Allow Base Plate Plan

There is currently no way to create a base plate plan in AutoDrafter. Please add it.
2 months ago in STAAD.Pro 0 Needs review

Update EN 1993-1-1 design code

Currently, EN 1993-1-1 provide in STAAD.Pro is 2005 edition. My request is to update the code to the latest edition, 2023.