Direct Analysis Method. Reduction stiffness for Strength and nominal stiffness for Service

According to the code and standard practice, stiffness reduction for DAM applies for Required Strength analysis, but for Design Strength calculation and for Service check, nominal stiffness is to be used. To be able to indicate Staad which combina...
over 1 year ago in STAAD.Pro 3 Already exists

Wind Load Graphic

Product: STAAD.Pro Description: Wind Load Graphic Details: Service Request 7001551689 created from the web by Milton Manos User Phone Number: 17406859217 I am requesting that STAAD.pro add a Wind Load Graphic (see enclosed example) to their calcul...
over 1 year ago in STAAD.Pro 1 Already exists

ACI 350

Add the concrete design code for environmental structures into STAAD for designing water retaining structures.
almost 3 years ago in STAAD.Pro 0 Already exists

STEEL ROD AS BRACING IN STAAD PRO CONNECT EDITION

I have model my truss and i want to add steel rod of 20mm diameter as a bracing on pipes carrying the truss, is this option available in Staad Pro Connect Edition?
over 3 years ago in STAAD.Pro 1 Already exists

FLAT SLAB, WITHOUT BEAMS

Option for modelling, analysis and design of a project with flat slab should be added in Staad Pro Connect Edition
over 3 years ago in STAAD.Pro 1 Already exists

Creation of Grid system & creation of views by Grid mark nos

I would suggest to add Grid system at column bases and also create floor levels. This would help us to isolate the grid views & floor levels during the time of geometric modelling.
over 3 years ago in STAAD.Pro 3 Already exists

LINE LOAD ON ANALYTICAL MODEL STAAD PRO CONNECT EDITION

Addition of partition wall load on slab should be added on analytical model in Staad Pro Connect Edition
over 3 years ago in STAAD.Pro 1 Already exists

AUTOMATIC GENRATION OF WIND LOAD AS PER INDIAN CODE

The following improvements should be made to Staad Pro 1.The automatic generation of wind load should be made available to Indian code also apart from American code.It will save lot of time in analysis and manual calculation. 2. Automatic creation...
over 3 years ago in STAAD.Pro 1 Already exists

ADDITION OF LINE LOAD ON PLATE

Option for adding wall load (partition wall) as line load direct on slab should be added
over 3 years ago in STAAD.Pro 1 Already exists

Connection Design

Connection Design模块中的AISC 341只能支持到05版规范吗,这个什么时候可以更新支持到16及22版规范,虽然ram connection可以支持到AISC 341 16及22版规范,但这需要设计人把每个节点的各个工况的内力提取出来,太耗精力了,实 现起来太国难
about 1 month ago in STAAD.Pro 1 Already exists