Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

STAAD.Pro

Showing 341

Add fire calculation in staad.pro

according to GB 51249-2017, steel structure needs to do the fire calculation and corresponding design. There are more and more security reviews about fire calculation, therefore it's necessary to add these content in staad.pro.
4 months ago in STAAD.Pro 1 Future consideration

EN1993-1-1 Eurocode 3 2005

STAAD.Pro- software is using EN1993-1-1 Eurocode 3 2005, - this is not the latest version of this design code. How do we go about updating this in STAAD-Pro ? We need to be using the latest design code for compliance with our EN1090 fabrication wo...
6 months ago in STAAD.Pro 1 Future consideration

Combined profile of a wide flange and channel as a single object

For Inclusion of built up section in standard I section combination with Channel section on top flange, which is widely used for gantry girder.
12 months ago in STAAD.Pro 5 Already exists

In wind load generator, please incorporate wind load in other directions such as X & Z. Also, wind load on roof truss & corners needs to be incorporated.

There is no way to add wind load in other direction in case of unclad building. For example : - staad taking load case only in one direction i.e. +X, whenever I try to add another case in z direction, previous case gets deleted automatically. So, ...
about 1 year ago in STAAD.Pro 3 Future consideration

IS 18168 : 2023 Earthquake Resistant Design and Detailing of Steel Buildings

It is new code introduced by IS Commitee for Steel Design. Those engineers working on STEEL Design across any industry will have to use all codal provisions suggested by IS8168. Accordingly STAAD Pro has to be upgraded.
9 months ago in STAAD.Pro 3 Future consideration

Slab deflection plots

Currently the only way to check the deflection of a slab is to review the deflected shape of the shells' mesh, or in the tabulated results. It would be very useful if the contour plots for shells included the option to contour deflections as well ...
9 months ago in STAAD.Pro 2 Future consideration

Allow an option to include Failed Member list in the report even when there are no failed members

In the new 2023 version, the new report builder doesn't allow you to include the failed member list when there aren't any failed members. v22 did allow for that and would report there are no failed members. Which was an easy concise way of saying ...
11 months ago in STAAD.Pro 1 Future consideration

Modify design parameter "PROFILE"

Design Parameter "PROFILE" seems to check only first 3 characters. If I understand correctly, STAAD already selects the lightest section only for the same kind of section as the current one, and the limit on the height can be set by variables DMAX...
4 months ago in STAAD.Pro 3 Future consideration

Calculation of Stability index Q as per annex E of IS456

To determine whether a column is a no sway or a sway column, stability index Q may be computed as given in annex-e of IS456. It's a very time consuming and cumbersome calculation while we are freezing the column sizes. if Q is directly calculated ...
4 months ago in STAAD.Pro 4 Future consideration

Include the moving load possibility in physical model

No description provided
7 months ago in STAAD.Pro 3 Needs review