Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 546

AutoDrafter - Save as PDF

Please allow option to save drawings from AutoDrafter to PDF.
5 months ago in STAAD.Pro 0 Needs review

AutoDrafter - Allow Base Plate Plan

There is currently no way to create a base plate plan in AutoDrafter. Please add it.
5 months ago in STAAD.Pro 0 Needs review

Add flexible / Semi rigid Diaphragm

Currently only rigid diaphragm option exists in Staad, we need to account for flexible diaphragms.
2 months ago in STAAD.Pro 0 Needs review

Story Shear for Wind and Seismic Loads:

At present, only storey drift & displacements are reported. There is a need to include storey shear values for both the X and Z directions to support comprehensive analysis.- There is an enhancement request already in place for this. For Euroc...
2 months ago in STAAD.Pro 2 Needs review

Inclusion of Steel Take off list & Member take off list in User Report

I have noticed that currently there is no option to include Steel take off & Member take off list while generating Report. I request that this option be included in future upgrade.
about 2 months ago in STAAD.Pro 6 Planned

AutoDrafter - Allow Isometric View (Full MTO Table)

It is only possible to create a plan/section by selecting a member at that location, and must be in the plane of either a plan or section. MTO take-off "drawing" only shows table - a great addition would be to add the isometric view of the structu...
5 months ago in STAAD.Pro 0 Needs review

SFA 2025. Failed postanalysis doesn't show why its failing

I have several spread footing analysis, and some indicate fail/pass as failed in red color, but bearing capacity is OK, now, I can see that safety factor is not OK by hovering the cursos over the footing, but that is all, I don't know the cause or...
28 days ago in STAAD Concrete 3 Planned

Add 75Deg had section database

in standard section data base only 90Deg hat is available, we are mostly using 75Deg hat
29 days ago in STAAD.Pro 2 Needs review

Request to keep beta angle 0

Sometimes, a member requires the assignment of a Beta Angle for a particular member, but after some iterations, it might not be needed. In the Beta Angle assignment tab, when someone defines a Beta Angle, it exists—but Beta Angle 0 is removed. In ...
about 1 month ago in STAAD.Pro 2 Already exists

implement the GFRP design of members as per ACI 440-1R-15.

The FRP rebar is future of replacement for mild steel rebar. it is most useful for design of member like beam, column, slab and foundation. in the infrastructure project it is mostly used. This is very useful for the future.
about 1 month ago in STAAD Concrete 0 Needs review