Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 493

Cold form section outside the standard library not designed in STAADpro as per IS801

STAADpro is not able to design cold form section outside the standard library or any user defined cold form section as per IS801. This is severe limitation as many users are using sections of their choice which are not in the library. This is espe...
14 days ago in STAAD.Pro 1 Future consideration

Design of double channel section in STAAD needs improvement

At present design of double channel in STAAD as per IS800 LSD is having certain work flow. It assumes higher MI as a major axis even if it can be about minor axis Y which is not correct. STAAD should consider section orientation as provided by use...
14 days ago in STAAD.Pro 1 Already exists

Design of double I section as column is required.

In most of the industrial sheds, double I section spaced apart is used as crane column and single I section is used to support the roof above. In present STAADpro ver 24 facility to design double I section as per IS800 LSD is not available . This ...
14 days ago in STAAD.Pro 1 Needs review

AutoDrafter - Do not show "Rigid" Member Symbol if member is a free end

AutoDrafter currently shows a rigid member symbol when a member has a free end with no other members connecting to that location. It would be great to remove these redundant symbols
about 1 month ago in STAAD.Pro 1 Needs review

AutoDrafter - Allow Option to Remove Member/Connection Type Legend

Member/Connection Type symbols sometimes crowd a drawing too much, or is too long (e.g., when dealing with Tee members taken by halfing a wide-flange section). It would be nice for an option within the Drawing Style Manager to activate/deactivate ...
about 1 month ago in STAAD.Pro 1 Future consideration

AutoDrafter - Manual Section Size Mark ID

Please allow users to manually override Mark IDs that are generated by AutoDrafter.
about 1 month ago in STAAD.Pro 0 Needs review

AutoDrafter - Clicking "Open in Microstation" does not work for OpenBuildings Designer

Please add support for OpenBuildings Designer being able to open drawings from AutoDrafter.
about 1 month ago in STAAD.Pro 0 Needs review

AutoDrafter - Allow Manual Assignment of Member/Connection Type

AutoDrafter appears to have some automated rules that are not perfect; would be nice to be able to override Member/Connection Type within AutoDrafter (e.g., select a column member, right click, modify properties, change 'Member Type').
about 1 month ago in STAAD.Pro 0 Needs review

Update of Canadian Code CSA 23.3 in STAAD Pro

For the design of concrete structures and foundations that will require permit approval in Canada, a recent code is expected. CSA code available in STAAD Pro Connect Edition is still CSA 23.3-94. Currently the latest code is 2019 but the 2014 is a...
over 2 years ago in STAAD Concrete 5 Planned

RCDC - Update Water Tank workflow using ACI code

Currently, water tank design is only available for the Euro Code. Please update for use with current ACI code.
8 months ago in STAAD Concrete 1 Needs review