Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

STAAD.Pro

Showing 127

Ai-Chat Gpt in Staad pro

Ai-Chat GPT can be used in Staad Pro for calculating Gust factors, which otherwise involve a lot of complicated formulas. Also, Reports can be presented in better ways with less time.
5 months ago in STAAD.Pro 0 Needs review

Automatic combinations should only include notional loads in the direction of the main lateral load

Hello, There’s no point in applying the notional load against other lateral loads. In STAAD, it’s possible that the Load Combination where automatically generated so the notional loads are generated for all directions even if they countermeasure t...
almost 2 years ago in STAAD.Pro 2 Needs review

property reduction factor for plates

dear staad pro team,i think more important things for shar wall system building for high rise building is property modifires for wall,it is misssing in staad pro i dont know why?all softwares have this important feature why is missing in staad?
almost 2 years ago in STAAD.Pro 6 Needs review

Beam utilization listing with drop down box

The "actual ratio" button in postprocessing mode is not working for a lot of users in Subsea7. This button is supposed to re-arrange beam utilizations from default beam number order, to utilization ascending order, and is very helpful. The problem...
12 months ago in STAAD.Pro 2 Needs review

Design of double I section as column is required.

In most of the industrial sheds, double I section spaced apart is used as crane column and single I section is used to support the roof above. In present STAADpro ver 24 facility to design double I section as per IS800 LSD is not available . This ...
6 months ago in STAAD.Pro 1 Needs review

Include the moving load possibility in physical model

No description provided
over 1 year ago in STAAD.Pro 3 Needs review

WIND CORNER PRESSURE AND ROOF IN WIND LOAD GENERATOR

Hello i would like to drop my suggestion for consideration, as we know up to now Wind Load generator, can only generate wind on panels. But during design we may have to apply corner wind pressure especially in connection design and also to apply w...
over 2 years ago in STAAD.Pro 2 Needs review

ASEC7 vertical structural irregularities check

The STAAD.Pro now can not check the the vertical structural irregularities 5a/5b in the ASCE 7 table 12.3-2 by ant command stream, but as the code demand, the designer need check this irregularities, it is very difficult and cost time for designer...
about 1 year ago in STAAD.Pro 1 Needs review

I sections with side plates

It is suggested to add I sections with side plates table under specifications user table manager tabs. Offshore brownfiled modificaitons work would involve adding side plates to existing I sections to increase its capacity.
over 1 year ago in STAAD.Pro 1 Needs review

OpenSTAAD Function to get CoG of the Model

It would be good to get a function in OpenSTAAD function to get the CoG of the Model.
about 1 year ago in STAAD.Pro 2 Needs review