Footing design - Enhancement related to Sliding and Uplift check

refer Service case Service Case 1441906: [CS0222209] Calculation basis for buoyancy and sliding check of pad footingsif the soil and self -weight is calculated with effect of buoyancy then there is no need to deduct it again to calculate net downw...
24 days ago in STAAD Concrete 0 Needs review

Beam design - Ductile detailing - failure case is not handled if diameter is restricted (higher diameter is not available)

refer service case - Service Case 1361907: RCDC software will be collapsed if the model contain an earthquake load combination.if higher diameter is not available and ductile detailing is not satisfied with the available diameter (with minimum spa...
24 days ago in STAAD Concrete 0 Needs review

Older version (11.00) file not opened in 23.00.02.43 version.

please refer to service case: Service Case 1365610 : [CS0156779] RCDC model in Previous version not working in latest version
24 days ago in STAAD Concrete 0 Needs review

Zone wise Design (Shear Design) for Tank Slabs

Currently in RCDC while designing the Tank Slab, RCDC considers the Overall Max Shear force irrespective of its location. Also, the slab is designed for the Max shear force. With this enhancement we look forward to get zone-wise design like we do ...
24 days ago in STAAD Concrete 0 Needs review

Slab design report enhancement if Area of Steel is governed by Shear design.

Enhancements: if the Area of Steel is governed by Deflection check and Shear design, it should be clearly covered in the design calculation report. if it is governed by a deflection check, RCDC does show it in the design calculation report, But wh...
24 days ago in STAAD Concrete 0 Needs review

E-tabs - Require facility to read one or more floors (group) for only beam design and slab design without data of full model.

refer Service case Service Case 1302678 : [CS0101576] Require facility to load one or more floors (group) for only beam design and slab design without data of full model for more information.
24 days ago in STAAD Concrete 0 Needs review

Beam Continuity - Issue found while modifying Beam Continuity in RCDC

Refer attached video. The issue occurs when we perform MERGE functionality after SPLIT functionality. A new issue is added on 7th September 2023.Issue related to Beam type after modifying beam continuity:Service Case 1276842: [CS0074014] Beam Desi...
24 days ago in STAAD Concrete 0 Needs review

Pilecap -Reinforcement drawing enhancements.

refer Service case Service Case 1268761: [CS0072116] Pile cap DrawingThe client has shared a sample drawing for reference.
24 days ago in STAAD Concrete 0 Needs review

Capacity Design as per NZS3404

Currently STAAD is performing only geometrical check of the members in accordance with Chapter 12 of NZS 3404. However, no design is performed based on the capacity design principles provided in this Chapter. As industries in New Zealand is increa...
25 days ago in STAAD.Pro 0 Needs review

Can we transfer maximum thermal load ( thermal 1, thermal 2, thermal 3) from autoPIPE pipelink to STAAD.Pro.

No description provided
27 days ago in STAAD.Pro 0 Needs review