Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 494

Automate the features of Stability analysis of raft foundation in SFA.

To determine stability analysis of raft foundation in SFA, Automatic features (by few clicks) is not available in SFA, rather much more manual, repetative, tedious and time consuming process, which lessens the efficiency and deliverables of softwa...
4 months ago in STAAD Concrete 1 Needs review

Pile supported "ring wall foundation design" features should be available in SFA.

For designing of "ring wall foundation" in SFA, as of now, only "Ground supported ring wall foundation design" available in SFA. But "Pile supported ring wall foundation design " isn't available. So it is necessary to implement the same in SFA.
4 months ago in STAAD Concrete 0 Needs review

Member Release Bubble - scale / highlight

At present member releases shown as circles at beam ends, makes the view a bit congested with node numbers ON, which makes it difficult to cross verify the DJ1 & DJ2 parameters. if we have an option to scale down the circle (or) introduce a 't...
over 1 year ago in STAAD.Pro 3 Future consideration

Warning based on superceded (old) code appears in Seismic analysis using IS 1893 pt 1.

STAAD Pro CONNECT Edition shows a warning based on IS 1893 part 1:2002, when the latest code available currently under use is IS 1893 part 1:2016. Kindly clarify why should warnings based on old codes appear when the user has specifically selected...
about 2 months ago in STAAD.Pro 0 Needs review

automated deflection check for concrete

No description provided
5 months ago in STAAD Concrete 3 Needs review

Include Indian Design Codes

your soft does not support codes for designing as per Indian Codes request if you could incorporate the same since the software is a wonder full product
3 months ago in STAAD Concrete 1 Needs review

Open STAAD function for changing a existing tapper property

Please add one open STAAD function in which we can edit existing tapper property it will same much time
5 months ago in STAAD.Pro 1 Needs review

Steel Check Code for all code, please make it uniform format

ANL file for steel code has changed format can you revert back again or atleast put to option on Track command to retain original format.
about 2 months ago in STAAD.Pro 0 Needs review

BEAM DEFLECTION CHECK IN RCDC

This check should be implemented in RCDC as we know during design the reinforcement area maybe needed to be increased in order to pass the beam deflection check
over 2 years ago in STAAD Concrete 1 Needs review

Add steel fireproofing specification to STAAD.pro Physical Modeler.

Currently, the only way to use STAAD.pro fireproofing specification is thru the Analytical Modeler. If you have a physical model, you have to break the connection and then edit the Input file to remove the "DO NOT EDIT" restrictions so that you ca...
about 2 months ago in STAAD.Pro 0 Needs review