Design of double I section as column is required.

In most of the industrial sheds, double I section spaced apart is used as crane column and single I section is used to support the roof above. In present STAADpro ver 24 facility to design double I section as per IS800 LSD is not available . This ...
about 2 months ago in STAAD.Pro 1 Needs review

BEAM DEFLECTION CHECK IN RCDC

This check should be implemented in RCDC as we know during design the reinforcement area maybe needed to be increased in order to pass the beam deflection check
over 2 years ago in STAAD Concrete 1 Needs review

Improve Curved Member Rendering and Analysis in STAAD.Pro

Executive Summary: This proposal outlines the need for enhancements to the rendering and analysis capabilities of curved members within the STAAD.Pro software. While curved members are essential for accurate modeling in various engineering applica...
5 months ago in STAAD.Pro 0 Needs review

Suggest and optimise RCC member section size

As staad pro capable to suggest and optimise steel member size, similarly staad should also be capable to suggest and optimize RCC members' section sizes, like beams, columns,shear walls, slabs, slabs etc. so that manual efforts would be minimised...
5 months ago in STAAD Concrete 1 Needs review

Tapered and stepped shear wall and retaining wall in RCDC

RCDC should read and and design shear wall and retaining wall having tapered section. Stepped shear wall design should also be done in RCDC.
5 months ago in STAAD Concrete 0 Needs review

Automate the features of Stability analysis of raft foundation in SFA.

To determine stability analysis of raft foundation in SFA, Automatic features (by few clicks) is not available in SFA, rather much more manual, repetative, tedious and time consuming process, which lessens the efficiency and deliverables of softwa...
5 months ago in STAAD Concrete 1 Needs review

Pile supported "ring wall foundation design" features should be available in SFA.

For designing of "ring wall foundation" in SFA, as of now, only "Ground supported ring wall foundation design" available in SFA. But "Pile supported ring wall foundation design " isn't available. So it is necessary to implement the same in SFA.
5 months ago in STAAD Concrete 0 Needs review

Automatically generate Image Reports

Please add an option to generate an image report for every load case. The image report are showing how the forces are affecting the structure (see attached screenshots). Currently it is only possible to manually create a screenshot for each load c...
over 2 years ago in STAAD.Pro 1 Needs review

Auto load combination for IS 802 part 4

It will be better is auto load combination for following IS codes, IS 802 Part 1/Sec1 2015 - Clause 13 - For Transmission tower Design IS 802 Part 4 2023 - Clause 13 - For latticed switchyard structure Design As of now only design code of IS 802 i...
4 months ago in STAAD.Pro 0 Needs review

automated deflection check for concrete

No description provided