Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 563

Inclusion of SS EN 1998-1 Seismic Action & Accidental Torsion

Application of seismic action (including accidental torsion) for structure in Singapore using EN 1998-1 is cumbersome. Request to include this code in future development.
12 months ago in STAAD.Pro 2 Needs review

Update STAAD Connection Design reports to docx format output

Currently, the reports from STAAD Connection Design are stored in .doc format which is outdated. Please update this to the current format supported by word.
2 months ago in STAAD.Pro 1 Planned

Add code checks for AISC 370

There is a new code for Stainless Steel that has been published by AISC. It would be nice to incorporate the code checks for AISC 370 for materials that have been selected as stainless steel.
about 3 years ago in STAAD.Pro 10 Future consideration

AutoDrafter - Do not show "Rigid" Member Symbol if member is a free end

AutoDrafter currently shows a rigid member symbol when a member has a free end with no other members connecting to that location. It would be great to remove these redundant symbols
7 months ago in STAAD.Pro 1 Needs review

AutoDrafter - Allow Option to Remove Member/Connection Type Legend

Member/Connection Type symbols sometimes crowd a drawing too much, or is too long (e.g., when dealing with Tee members taken by halfing a wide-flange section). It would be nice for an option within the Drawing Style Manager to activate/deactivate ...
7 months ago in STAAD.Pro 1 Future consideration

AutoDrafter - Manual Section Size Mark ID

Please allow users to manually override Mark IDs that are generated by AutoDrafter.
7 months ago in STAAD.Pro 0 Needs review

AutoDrafter - Clicking "Open in Microstation" does not work for OpenBuildings Designer

Please add support for OpenBuildings Designer being able to open drawings from AutoDrafter.
7 months ago in STAAD.Pro 0 Needs review

AutoDrafter - Allow Manual Assignment of Member/Connection Type

AutoDrafter appears to have some automated rules that are not perfect; would be nice to be able to override Member/Connection Type within AutoDrafter (e.g., select a column member, right click, modify properties, change 'Member Type').
7 months ago in STAAD.Pro 0 Needs review

SFA 2025. Failed postanalysis doesn't show why its failing

I have several spread footing analysis, and some indicate fail/pass as failed in red color, but bearing capacity is OK, now, I can see that safety factor is not OK by hovering the cursos over the footing, but that is all, I don't know the cause or...
2 months ago in STAAD Concrete 3 Planned

Add 75Deg had section database

in standard section data base only 90Deg hat is available, we are mostly using 75Deg hat
2 months ago in STAAD.Pro 2 Needs review