Viewing the utilization ratios in the GUI is very cumbersome when evaluating the analysis results. Please consider the following updates to the GUI interface.
1) The ability for user to change the decimal points on the screen labels (0.01 is preferred default instead of the current 0.001, which clutters the screen).
2) The ability for user to show labels only for utilizations with user defined boundaries. For example, have the screen display only the labels for elements with utilizations above 0.75. Or only utilizations below 0.50. Let the user have full capability to display whatever range of utilizations they want to display on the screen.
3) The ability for user to view utilizations for each individual load case / combination in the Load List in a run that has been code checked, not just the software determined governing case.
Thank you for posting this idea. However the capability exists. If you right click on the graphs window and click on the Design Results tab. From here you can choose which results are labelled.
The idea of displaying the result for a load case can be achieved for some design codes such as newer AISC 360 editions by defining them as separate code checks using a load list with each code check and then you can review each one