Using arbitrary Young's modulus (E) in AIJ2005 code calculations
In the current AIJ2005 code allowable stress calculation of STAAD.Pro, the Young's modulus is fixed at 205000 (N/mm2).
On the other hand, in the AIJ2002 code, by using the YNG=1 parameter, the Young's modulus used in the frame analysis can be use...
over 1 year ago
in STAAD.Pro
3
Future consideration
A print command such as "PRINT JOINT FORCES LIST 1 2 3 etc." that would output all the member end forces at a specified node, for the specified load cases. This is currently possible using macros/openSTAAD, but would be very helpful if added to th...
almost 2 years ago
in STAAD.Pro
3
Will not implement
Add the ASME-STS-1 2021 file as an option for the results of the analysis. There are only four equations from ASME, then everything defaults to AISC 2016, so most of the work is done.
about 2 years ago
in STAAD.Pro
6
Future consideration
every time when we update software, it should be notified to take necessary backup of added section for cold form, it is really painful doing same work in 1-2 month while software is being updated. it will save designerr time
over 2 years ago
in STAAD.Pro
1
Future consideration
1. Connection Tags view - this window should have "on the top function" To be above the other windows when user click the member or node. 2. Connection Tag Check Results - this window should be "expandable". 3. Check Connection Tags - this window ...
over 4 years ago
in STAAD.Pro
1
Future consideration
Relax Floor Load Command Tolerances with Node Coordinates
The floor load command does not work properly for 1 way load distribution if a node is not perfectly inline with adjacent nodes. Example: 2 nodes have a Z coordinate of 8.333 however the 3rd has 8.333333 and the floor load command does not populat...
Custom equivalent lateral force procedure and seismic definition/custom model response in Staadpro CE
I am tasked with designing a steel support structure in Staadpro connect edition. As part of the design, I need to conduct a seismic analysis of the frame. The steel structure is 12 m high and needs to be designed according to the New Zealand seis...
over 5 years ago
in STAAD.Pro
1
Future consideration
Dear Staff
Please I have some suggestions for the future development of STAAD as:
1- Nonlinear pushover analysis for CONCRETE structures
2- Analysis & Design of MASONRY Structures
3- Analysis & Design of COMPOSITE steel-concrete COLU...
Ductile Wall Design AS Per EN 1998:2004(Seismic code)
RCDC does an excellent job performing seismic ductile wall design according to Eurocode, yet the following areas needs improvement or clarification:
1. According to EN 1998:2004 section 5.4.2.4(4 and 5), seismic walls shall be designed for moment...
over 3 years ago
in STAAD.Pro
0
Future consideration