EN1993-1-1 Eurocode 3 2005

STAAD.Pro- software is using EN1993-1-1 Eurocode 3 2005, - this is not the latest version of this design code. How do we go about updating this in STAAD-Pro ? We need to be using the latest design code for compliance with our EN1090 fabrication wo...
about 1 year ago in STAAD.Pro 1 Future consideration

Auto Wind load for roofing

Implement a method to generate loading on roof structures as per the IS 875 part 3 wind load code using the Cpe method using the values in Table 8 / 9
almost 3 years ago in STAAD.Pro 6 Future consideration

Auto wind load generation for roof/purlins..

Frequently used for design of all steel structure with shed/roof CONCERN CODE(ALL) especially IS 875 part 3: 1-Sir, staad CE has support the auto wind load as for clad/unclad buildings, this wind load is applied on the surfaces/periphery of buildi...
over 2 years ago in STAAD.Pro 3 Future consideration

expand decimal numbers from 2 to 3+ in Property dialog box

currently, only 2 decimal numbers are displayed for plate thickness. when there are different plate thickness are input, and the thickness differences is on the 3rd decimal number, it will be hard to figure out which one is which, since they are d...
about 2 years ago in STAAD.Pro 1 Future consideration

Improve Connection Tags

1. Connection Tags view - this window should have "on the top function" To be above the other windows when user click the member or node. 2. Connection Tag Check Results - this window should be "expandable". 3. Check Connection Tags - this window ...
over 4 years ago in STAAD.Pro 1 Future consideration

Custom equivalent lateral force procedure and seismic definition/custom model response in Staadpro CE

I am tasked with designing a steel support structure in Staadpro connect edition. As part of the design, I need to conduct a seismic analysis of the frame. The steel structure is 12 m high and needs to be designed according to the New Zealand seis...
over 5 years ago in STAAD.Pro 1 Future consideration

Ductile Wall Design AS Per EN 1998:2004(Seismic code)

RCDC does an excellent job performing seismic ductile wall design according to Eurocode, yet the following areas needs improvement or clarification: 1. According to EN 1998:2004 section 5.4.2.4(4 and 5), seismic walls shall be designed for moment...