Can we transfer maximum thermal load ( thermal 1, thermal 2, thermal 3) from autoPIPE pipelink to STAAD.Pro.

No description provided
1 day ago in STAAD.Pro 0 Needs review

Improvement Proposal for the Visualization and Detail of Reinforcement Steel in STAAD Foundation Advanced (SFA) Version 2024

Although the current version of SFA 2024 allows users to view the proposed reinforcement using the Detailing option and take a manual screenshot from the Report tab to include it in the report, this image must be added manually and can only be pla...
about 2 months ago in STAAD Concrete 0 Needs review

Automatic effective length calculation

In staad pro CE, in analytical modeler, when we add new node/s, the existing member is divided into segments, and the program takes length/effective length of that member as part, not takes as a whole member length about its major or minor axis ac...
almost 3 years ago in STAAD.Pro 22 Shipped

Moving load in vertical plane and horizontal plane as well.

As of now, moving load feature is available only in vertical plane. But moving load in horizontal plane isn't available yet. But, as per industry demand, moving load to be applied longitudinal and transverse direction, simultaneously. Staad pro s...
5 months ago in STAAD.Pro 0 Needs review

EN1993-1-1 Eurocode 3 2005

STAAD.Pro- software is using EN1993-1-1 Eurocode 3 2005, - this is not the latest version of this design code. How do we go about updating this in STAAD-Pro ? We need to be using the latest design code for compliance with our EN1090 fabrication wo...
about 1 year ago in STAAD.Pro 1 Future consideration

Auto Wind load for roofing

Implement a method to generate loading on roof structures as per the IS 875 part 3 wind load code using the Cpe method using the values in Table 8 / 9
almost 3 years ago in STAAD.Pro 6 Future consideration

Auto wind load generation for roof/purlins..

Frequently used for design of all steel structure with shed/roof CONCERN CODE(ALL) especially IS 875 part 3: 1-Sir, staad CE has support the auto wind load as for clad/unclad buildings, this wind load is applied on the surfaces/periphery of buildi...
over 2 years ago in STAAD.Pro 3 Future consideration

Wind loading on cylindrical structures as per IS 1875 part 3

Provide a method to create wind loading on Cylindrical Structures as per Wind Pressure coefficients in clause 7.3.3.7 using Table 19 of IS 875 Part-3 2015
over 1 year ago in STAAD.Pro 4 Needs review

Please add the following South African Concrete Standards (SANS) to the RCDC (STAAD Advance Concrete Design) Program

Main SA Concrete Design Code SABS 10100-1:2000 Edition 2.2. The Structural use of Concrete Part 1: Design Supplementary SA Concrete Design Codes SABS 10100-2:2014 Edition 3 The Structural use of Concrete Part 2: Materials and Execution of Work SAN...
almost 2 years ago in STAAD Concrete 1 Needs review

Modify design parameter "PROFILE"

Design Parameter "PROFILE" seems to check only first 3 characters. If I understand correctly, STAAD already selects the lightest section only for the same kind of section as the current one, and the limit on the height can be set by variables DMAX...
about 1 year ago in STAAD.Pro 3 Shipped